A diesel dual-fuel system uses diesel together with another fuel during at least part of operation. In a common natural-gas arrangement, diesel injection provides the ignition source for a gas-and-air charge. It is different from a bi-fuel system that selects one fuel or the other. The US Department of Energy's Alternative Fuels Data Center distinguishes these vehicle configurations.
How the fuels work together
One documented arrangement retains the diesel injection system and introduces natural gas into the intake. A controlled diesel pilot initiates combustion of the mixture. The gas fraction and pilot amount change with operating conditions; a diesel-pilot system cannot run on gas alone unless it has a separate ignition strategy. DOE's natural-gas engine technology review describes this arrangement and its operating trade-offs. Other dual-fuel architectures introduce fuel differently.
Propane and natural gas are different fuels with different properties and storage systems. A research study examined both as secondary fuels with diesel pilot injection in a particular test engine; its findings are not a calibration or performance guarantee for a road vehicle. US DOE Office of Scientific and Technical Information: dual-fuel research.
Control and validation
A complete system must coordinate both fuel supplies with engine load, injection timing, air supply, temperatures and protection functions. DOE notes that premixed natural-gas operation can encounter knock at high load and misfire when the mixture is very lean; the fuel split therefore varies through the operating range. Smoke, nitrogen oxides, unburned hydrocarbons and methane emissions depend on the fuel, combustion and aftertreatment combination. A gain or reduction measured on one engine cannot be assumed for another.
Assess the approved conversion or engine manufacturer's documentation for the exact engine, gas storage, shut-off, control, leak testing, maintenance and emissions system. Confirm how faults, a depleted gas supply and loss of electrical power are handled. Retain the applicable diagnostics and aftertreatment, and have the installation and calibration validated by a competent specialist. DOE's conversion guidance explains the role of qualified conversion systems in the US; requirements elsewhere differ.
For the diesel side, see tuning diesel injection systems and diesel smoke limits. Related aftertreatment is described in selective catalytic reduction and diesel particulate filters.