Tuning Wiki
Browse AUMOVIO

Accessory connectors in AUMOVIO MK 100 UHP technical manual v2.1, figures 12–14, pages 17–18. These are accessory connector positions, not HECU positions. This applies to the described supplied kit hardware; check actual part numbers, connector orientation and revised supplier documentation.

Supplied PS20 external brake-pressure sensor

The manual identifies PS20 part 10.0522-9963. It warns against using a different external pressure sensor with this kit.

Sensor contactFunction
1Ground
2Signal output
3Power supply positive

Supplied IMU connector

IMU contactFunction
1Ground
2CAN IMU low
3CAN IMU high
412 V supply

Supplied rotary mode switch

Switch pinWire colourUHP HECU connection
1Red22, ABS_MODE_SW_SENSEEP
2White23, ABS_MODE_SW_SIG
3Black29, ABS_MODE_SW_GND

The manual warns to use the supplied switch. Consult the maker’s diagrams for connector face and orientation, and the separate HECU pinout for the ABS-only unit. Source: AUMOVIO MK 100 UHP technical manual v2.1, pages 17–18 and 22.