Exhaust gas temperature (EGT) is a useful trend and protection input when its measurement point and operating conditions are understood. It is not a direct measurement of piston temperature, cylinder pressure or air–fuel ratio, and one reading cannot identify the cause of a hot cylinder on its own.

Where the probe is placed

A probe in an individual exhaust runner samples that cylinder; one in a collector or after a turbine sees a combined stream at a different point in the exhaust. These readings are not interchangeable. When comparing cylinders, use comparable probe types, distances from the head and insertion depths, following the engine and sensor manufacturer's instructions. Haltech's EGT guide explains installation consistency and response differences.

Thermocouples need a compatible input or amplifier and correct configuration. Probe construction affects response: a slower probe can miss or delay a short event. Check the condition, range, wiring and channel assignment before treating a difference as an engine fault.

Interpreting a change

EGT changes with operating point, fuel and ignition conditions, exhaust flow and sensor location. A higher or lower reading alone does not uniquely identify a rich or lean cylinder: mixture, combustion timing, misfire and measurement differences can all affect the result. Compare the same operating point over repeated runs and use appropriate supporting evidence such as lambda, ignition, fuel pressure, engine speed and load. See mixture tuning and logging.

Individual-cylinder probes can help identify a persistent difference that merits investigation; first rule out probe and installation differences and mechanical or fuelling faults. Do not automatically adjust fuel until all probes read the same number. Some ECUs support per-cylinder EGT monitoring and control, but the available channels and behaviour depend on the particular system. Haltech's Elite documentation gives one example.

Limits and protection

There is no single safe EGT limit for all engines or probe locations. Establish limits from the relevant engine, turbocharger, sensor and controller information, and account for delay and the intended operating duration. A configured warning or shutdown is an additional layer of protection, not proof that every component remains within its temperature limit. Haltech documents a per-cylinder shutdown function for a specific configuration, including a delay and reset behaviour; other systems differ.

For factory sensor faults and diagnosis see common EGT sensor faults. Aviation mixture procedures are engine- and aircraft-specific and should not be transferred to an automotive tune.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 1: Using exhaust gas temperature in engine tuning

Exhaust gas temperature (EGT) is a useful trend and protection input when its measurement point and operating conditions are understood. It is not a direct measurement of piston temperature, cylinder pressure or air–fuel ratio, and one reading cannot identify the cause of a hot cylinder on its own.

Where the probe is placed

A probe in an individual exhaust runner samples that cylinder; one in a collector or after a turbine sees a combined stream at a different point in the exhaust. These readings are not interchangeable. When comparing cylinders, use comparable probe types, distances from the head and insertion depths, following the engine and sensor manufacturer's instructions. Haltech's EGT guide explains installation consistency and response differences.

Thermocouples need a compatible input or amplifier and correct configuration. Probe construction affects response: a slower probe can miss or delay a short event. Check the condition, range, wiring and channel assignment before treating a difference as an engine fault.

Interpreting a change

EGT changes with operating point, fuel and ignition conditions, exhaust flow and sensor location. A higher or lower reading alone does not uniquely identify a rich or lean cylinder: mixture, combustion timing, misfire and measurement differences can all affect the result. Compare the same operating point over repeated runs and use appropriate supporting evidence such as lambda, ignition, fuel pressure, engine speed and load. See mixture tuning and logging.

Individual-cylinder probes can help identify a persistent difference that merits investigation; first rule out probe and installation differences and mechanical or fuelling faults. Do not automatically adjust fuel until all probes read the same number. Some ECUs support per-cylinder EGT monitoring and control, but the available channels and behaviour depend on the particular system. Haltech's Elite documentation gives one example.

Limits and protection

There is no single safe EGT limit for all engines or probe locations. Establish limits from the relevant engine, turbocharger, sensor and controller information, and account for delay and the intended operating duration. A configured warning or shutdown is an additional layer of protection, not proof that every component remains within its temperature limit. Haltech documents a per-cylinder shutdown function for a specific configuration, including a delay and reset behaviour; other systems differ.

For factory sensor faults and diagnosis see common EGT sensor faults. Aviation mixture procedures are engine- and aircraft-specific and should not be transferred to an automotive tune.

Revision 1: Using exhaust gas temperature in engine tuning

Exhaust gas temperature (EGT) is a useful trend and protection input when its measurement point and operating conditions are understood. It is not a direct measurement of piston temperature, cylinder pressure or air–fuel ratio, and one reading cannot identify the cause of a hot cylinder on its own.

Where the probe is placed

A probe in an individual exhaust runner samples that cylinder; one in a collector or after a turbine sees a combined stream at a different point in the exhaust. These readings are not interchangeable. When comparing cylinders, use comparable probe types, distances from the head and insertion depths, following the engine and sensor manufacturer's instructions. Haltech's EGT guide explains installation consistency and response differences.

Thermocouples need a compatible input or amplifier and correct configuration. Probe construction affects response: a slower probe can miss or delay a short event. Check the condition, range, wiring and channel assignment before treating a difference as an engine fault.

Interpreting a change

EGT changes with operating point, fuel and ignition conditions, exhaust flow and sensor location. A higher or lower reading alone does not uniquely identify a rich or lean cylinder: mixture, combustion timing, misfire and measurement differences can all affect the result. Compare the same operating point over repeated runs and use appropriate supporting evidence such as lambda, ignition, fuel pressure, engine speed and load. See mixture tuning and logging.

Individual-cylinder probes can help identify a persistent difference that merits investigation; first rule out probe and installation differences and mechanical or fuelling faults. Do not automatically adjust fuel until all probes read the same number. Some ECUs support per-cylinder EGT monitoring and control, but the available channels and behaviour depend on the particular system. Haltech's Elite documentation gives one example.

Limits and protection

There is no single safe EGT limit for all engines or probe locations. Establish limits from the relevant engine, turbocharger, sensor and controller information, and account for delay and the intended operating duration. A configured warning or shutdown is an additional layer of protection, not proof that every component remains within its temperature limit. Haltech documents a per-cylinder shutdown function for a specific configuration, including a delay and reset behaviour; other systems differ.

For factory sensor faults and diagnosis see common EGT sensor faults. Aviation mixture procedures are engine- and aircraft-specific and should not be transferred to an automotive tune.