A Technical University of Liberec engine-dynamometer study describes an experimental Škoda 1.2 HTP engine converted to compressed natural gas (CNG). It is useful when investigating the interaction between a petrol ECU and an additional gas controller. The researchers identify the replacement petrol controller only as Simos 9; they do not provide its suffix, software identifier or calibration. The test engine and conversion are not evidence that every Simos 9, or a particular Simos 9.1 vehicle, has the same strategy or hardware.

What was tested

The paper describes a 40 kW, naturally aspirated three-cylinder EA111.03D laboratory engine originally equipped with Simos 3PG. The researchers then installed a Škoda-prepared Simos 9 ECU, and a separate BRC Sequent Fastness sequential CNG injection system with its own gas injectors, pressure and temperature sensors. The paper describes the gas system as connected to engine-speed, upstream oxygen-sensor, petrol-injector and throttle signals. This was a test installation, not a documented production Simos 9 fitment or retrofit procedure.

In the described conversion, the gas controller used petrol fuelling commands to derive CNG fuelling. Its calibration software included correction maps and fuel-changeover conditions. Those maps belong to the auxiliary gas system in this study; the paper does not identify Simos internal maps, their axes, addresses or scaling. The control and wiring arrangements of other conversion kits may differ.

Observed transitions and feedback

The authors report unstable fuelling after initial setup, including excess enrichment during a load decrease and misfire followed by cylinder deactivation. They report that another calibration reduced the problem. They also describe difficult transitions from high load to idle, and an operating region in which the gas-controller correction exceeded the feedback range described for the experiment. After changing the auxiliary controller's treatment of that region, they report that the transitions improved. These are observations and operator changes on one test engine, not a general instruction to disable closed-loop control or copy its numerical settings.

For a vehicle with a similar complaint, record the exact petrol ECU and gas-controller identities, fuel mode and changeover status, fault memory and recent work. If correctly defined channels are available, compare petrol-injection command, gas-injection command, engine speed, load or manifold pressure, throttle and oxygen-sensor feedback through the transition; check whether each signal is measured, requested or calculated and whether the logger captures the event. A fault present on one fuel and absent on the other is useful evidence, but it does not by itself identify a faulty controller or justify changing the petrol calibration. Compare repeatable operating conditions and follow the conversion supplier's and vehicle manufacturer's diagnostic procedures.

Ignition intervention and fault interpretation

After adding ignition timing correction through the CNG unit, the researchers observed more frequent crankshaft and camshaft sensor plausibility errors. They did not establish the mechanism; the paper proposes possible signal interference or altered timing as explanations. The researchers' interpretation and recommendation are specific to that experimental installation and do not establish that every gas system modifies these signals. Investigate the actual wiring, power supplies, sensor signals and mechanical timing using the appropriate procedures rather than assuming a calibration fault or suppressing the diagnostic.

The paper reports experimental lambda and timing settings, but these were associated with particular hardware and tests and are not transferable targets. The paper itself reports unresolved sensor faults and concerns about exhaust temperature under one setup. Fuel composition, converter configuration, ignition equipment and operating conditions matter; a safe calibration cannot be inferred from the study alone.

Source and limits

Jan Mareš, “Complication by Conversion of Spark Ignition Engine to CNG Engine”, Technical University of Liberec, pages 155–160. Academic report of one laboratory engine and auxiliary fuel system. Controller suffix, binary and ECU map definitions are not given. Accessed 17 November 2026.