This reference records selected ignition, lambda and knock-related labels and axis inputs from the public C30 archive, which includes an A2L definition named SC2C3031_Ce_ro.a2l. Its descriptions identify an EA888 C30 project with EPK SC2C300. The archive name associates it with Simos 12.2 and 06K906070F; origin, authenticity, rights, completeness, the A2L's correspondence to the included HEX, and vehicle applicability are unverified. The A2L describes parameters and inputs, not actual values or proof of runtime behaviour. Match the exact software and independently verify definitions before use.

Basic and reference ignition definitions

The A2L describes ip_iga_bas_ivvt_vvl_port_h[0][0][0] and ip_iga_bas_ivvt_vvl_port_l[0][0][0] as basic ignition angle maps for high and low port-flap positions respectively, for available valve-lift curves at the current camshaft phasing. The described inputs are n, engine speed, and maf_fg_cyl_ign[0][0], fresh-gas mass flow out of the intake manifold per stroke with delay. ip_iga_ref_ivvt_vvl_port_h[0][0][0] is described as a reference ignition angle map for the high port-flap position with the same named inputs.

Other indexed entries exist. These names alone do not establish which physical hardware is fitted, what each index selects, when a map is active or how it contributes to final ignition timing. In particular, do not treat reference ignition as automatically equivalent to commanded cylinder timing.

ip_iga_bas_cmb_mod_cor[0] is described as a basic ignition correction for different combustion modes, with inputs n_32 (engine speed, resolution 32 rpm) and maf_fg_cyl_ign_1 (the scalar delayed fresh-gas mass-flow quantity). ip_iga_bas_low_ron is described as an intermediate basic-ignition correction based on fuel quality, with inputs maf_stk_fg_pred, predicted air mass for basic fuel-injection calculation, and n_32. Neither label establishes a physical fuel-quality sensor, selection logic or appropriate correction values.

Lambda and temperature relationships

The definition calls ip_lamb_bas[0] a basic lambda setpoint, with n_32 and maf as inputs; the latter is described as predicted air mass for calculating basic fuel injection. This description is not evidence that the input is a physical mass-air-flow sensor reading, or that this entry is the final lambda target under every operating condition.

ip_fac_iga_bas is described as a factor for lambda interpolation for basic ignition, using lamb_ratio and maf_fg_cyl_ign_1. The definition describes lamb_ratio as the current lambda ratio for the interpolation factor. The factor is not itself an ignition setpoint, and the interpolation formula is not established by these labels.

ip_iga_bas_temp_tco_cor and ip_iga_ref_temp_tco_cor are respectively labelled temperature corrections for basic and reference ignition angle. Both name n_32 and tco (coolant temperature) as inputs. Their presence does not establish when either correction is applied or its calibration values.

Knock-window and response labels

The A2L describes ip_knkwb[0] as the beginning and ip_knkwd[0] as the duration of the knock-measurement window for each cylinder. It describes ip_iga_dec_knk as spark retard at recognised knocking. Each names n_32 and maf_h_rng_knk as inputs; the latter is described as mass air flow in a high range with hysteresis. The window and response definitions are distinct. The array index does not by itself identify a physical cylinder, and these descriptions do not establish detection thresholds, control logic or a physical airflow-sensor source.

Using the information

Record ECU hardware and software identification, calibration, fuel and vehicle configuration, then confirm the exact A2L-to-file match, axes and units before drawing conclusions. Use logger channels supported and defined for that ECU to compare target and actual lambda, ignition timing, knock corrections and relevant temperatures under comparable conditions. Check channel meanings, sampling and availability: no displayed retard is not proof that knock did not occur. The labels above provide starting points for investigation, not a validated tuning recipe. Preserve knock detection and protections while diagnosing.

For related C30 torque and protection labels, see Simos 12.2 C30 torque and protection definition reference. Injection hardware and operating modes depend on the installation; see Simos 12 1.8 TSI direct and port injection diagnosis for the documented SEAT example.

Source and identification

TorqueCloud public Simos 12.2 C30 archive, SC2C3031_Ce_ro.a2l, accessed 17 November 2026. The extracted A2L is 42,598,995 bytes; SHA-256 7b5194ebeac25329b69ec0880251fc9e9ce50e4a795b72fd8608f6314c052fad. This hash identifies the examined file; it does not authenticate it or prove compatibility.