Volkswagen Self-Study Programme 222 describes electronically mapped cooling on its 1.6-litre, 74 kW APF example using Simos 3.3. Its temperature maps, thermostat and fan logic matter when interpreting a baseline or assessing a calibration. The description is specific to that system: a Simos 3.3 label alone does not prove a different engine has the same cooling hardware or strategy.
How the target is selected
VW describes two coolant-temperature setpoint maps. One depends on engine speed and load (air mass); the other depends on road speed and intake-air temperature. The lower of their outputs is used as the setpoint. A separate pre-control duty map uses setpoint and engine speed, while two maps control the temperature difference associated with first and second radiator-fan speeds. The control functions are calculated every second. This is a description of the documented logic, not a published map address, factor or complete calibration. SSP 222, pages 15–17 and 20–21.
The programme illustrates roughly 95–110°C under part throttle and 85–95°C under full throttle for its mapped system; these are operating ranges in a training example, not universal targets or fault thresholds. Its heater-control example also shows cabin heat demand influencing coolant-temperature control. Record engine load, speed, road speed, intake temperature and heater setting when comparing runs: one coolant reading on its own cannot establish whether a setpoint or physical cooling fault is present. SSP 222, pages 6 and 16–17.
Thermostat heater and the two senders
The F265 thermostat contains a wax expansion element and an electrical heater. The heater warms the element so it opens the radiator circuit earlier than the element would on coolant temperature alone; it does not heat the coolant as its primary purpose. The ECU controls heating with a pulse-width-modulated signal. In VW’s explanation more heating shifts operation toward lower coolant temperature. The wax element remains a mechanical part of the control and the radiator circuit can operate in intermediate positions; duty alone does not prove that the thermostat moved or that the cooling circuit is flowing correctly. SSP 222, pages 9, 12–13 and 19.
G62 reports temperature at the engine outlet; G83 is at the radiator outlet. They do not measure the same location. Their difference changes with coolant flow, radiator heat rejection, air flow and operating state, so compare them over time rather than substituting one for the other. The source describes fan control using coolant-temperature information and fan stages, not a single universal on-temperature. SSP 222, pages 18 and 21.
Fallbacks can change the log
For the system in SSP 222, loss of G62 causes a 95°C substitute value for cooling control and continuous first fan speed. With G83 failure, temperature control remains active and first fan speed remains active; a further threshold can bring in the second stage. With both senders failed, VW describes maximum voltage to the thermostat heater and continuous second fan speed. These are documented diagnostic responses, not proof that any particular scan-tool display shows the substituted value. Check faults and status as well as the value itself. SSP 222, page 18.
VW also describes an unpowered thermostat heater reverting to mechanical element control with first fan speed continuously activated, and different fallback actions for fan output-stage faults. Fan operation can therefore be a protective response rather than evidence of a modified fan map. Follow the vehicle-specific workshop test; a healthy commanded duty is not proof of a healthy heater circuit. SSP 222, pages 19 and 21.
Practical baseline and calibration review
- Record engine code, controller hardware and software identification, cooling-system equipment, faults, modifications and ambient conditions. Confirm the car actually has the APF-style mapped cooling system before applying this example.
- From a safe cold start through warm-up and comparable light- and higher-load conditions, record G62, G83, engine speed, load or air mass, road speed, intake temperature, fan status and thermostat duty or command if the diagnostic tool supports them. Note heater setting and whether the displayed values are measured, calculated or substituted. Allow for thermal delay and confirm sensor location and units.
- If temperature does not follow the expected trend, assess electrical power and control, senders and wiring, coolant condition and level, trapped air, radiator, fan and thermostat mechanics using the correct repair procedure. Do not infer a map fault solely from a single reading or fan event.
- For a proposed change, match the definition to the exact software and verify the setpoint maps, their inputs and units, interaction with the other setpoint, pre-control and fan functions. A change to only the higher setpoint map may have no effect when the lower output governs. Validate the result under comparable conditions; the factory training text does not provide map addresses, verified tuning values or evidence that lowering a target alone increases power.
Sources
- Volkswagen Self-Study Programme 222: Electronically Mapped Cooling System, especially pages 6–7, 9–13 and 15–21. APF example, map selection, thermostat, senders, fans and fallback behaviour. A training description, not a workshop procedure. Accessed 17 November 2026.
- TRW Easycheck application list 4.0.0. Product-specific Golf Mk IV APF Simos 3.3 diagnostic listing; not universal application or programming coverage. Accessed 17 November 2026.