The following positions are for the eight-way Deutsch connector on the BRE MK60E5-to-Haltech CAN gateway in the manufacturer’s installation instructions v1.2, revised 19 September 2024. They are gateway connector numbers, not ABS control-unit or generic Haltech ECU connector numbers. Confirm connector orientation and version against the source. BRE instructions, page 1.
| Gateway position | Function |
|---|---|
| 1 | Ground |
| 2 | CAN 1 low — Haltech side |
| 3 | CAN 2 low — MK60E5 PT-CAN side |
| 4 | Not used |
| 5 | Not used |
| 6 | CAN 2 high — MK60E5 PT-CAN side |
| 7 | CAN 1 high — Haltech side |
| 8 | 6–30 V DC supply |
BRE specifies ignition-switched supply and shows the gateway CAN2 connected to MK60E5 PT-CAN high at ABS pin 30 and low at ABS pin 15 for this documented configuration. Match the actual module and harness; do not apply this to the original non-E MK60. The product page also lists MK60E1 compatibility, with its pressure-signal limitation; confirm its exact wiring with the supplier.