Removed text is struck through; added text is highlighted.
Manufacturer product photograph: Cosworth. Permission to republish confirmed by the user.
The Antares 4 is a Cosworth Antares family ECU and vehicle controller. Cosworth describes it as a lower-cost entry in its Antares range while retaining data-logging and powertrain-control functions. Cosworth product information.
Manufacturer product specification
Cosworth's Antares 4 product page describes optimisation for 4-cylinder GDI or 8-cylinder port injection; it lists 3 CAN ports, 4 GB logging, two onboard lambda inputs, two knock inputs and three H-bridge pairs. Maximum counts include alternative functions, so they are not necessarily simultaneously available. Confirm hardware and enabled strategy against the current build.
A separate family comparison leaflet gives different cylinder/driver figures from the product page; these should not be reconciled without revision-specific confirmation. Use the exact build sheet and software from Cosworth for the installation.
Identification and control
Confirm the exact ordered configuration and obtain the matching connector and calibration documents from Cosworth. Antares family feature headlines do not establish that every feature is enabled on this particular unit. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
Software and support
Cosworth's Pectel application notes cover model-specific strategies; confirm toolchain and access level with the supplier. See the Cosworth Pectel and Antares family for related controllers.
Connector schedules in Cosworth’s Antares 4 sheet
The tables list all 66 numbered positions for each of four connectors from Cosworth’s Antares 4 product sheet, cover version 0.3. Signal names and connector part numbers follow that sheet; “not labelled in source” denotes an empty signal cell and must not be read as a confirmed unused pin. Where the sheet shows two pins for one signal, both are listed individually. Consult the source for the paired-pin notation, wiring, current limits, optional functions, grounds and orientation.
Document identification discrepancy: the cover and ordering table identify Antares 4 and product 01E-501154, but the final page identifies document 29E-501156-P, revision 1.0; 01E-501156 is identified elsewhere by Cosworth as Antares 6. The cover and final page also show different version numbers. Confirm the document and pin assignments for the exact unit directly with Cosworth before wiring.
C1 — AS218-35PN-943B; mating AS618-35SN
PinSignal in source1INJLS2/PWM42INJHS2/PWM33IGN4/PWM464INJLS1/PWM25INJHS1/PWM16BATT-7IGN4/PWM468IGN3/PWM459IGN2/PWM4410INJHS4/PWM711BATT-12BATT-13Serial2_TX_CTRL14IGN3/PWM4515IGN2/PWM4416IGN1/PWM4317INJLS4/PWM818BATT+19BATT-20BATT-21Serial2_RX_CTRL22SerialDBG_RX_LOG23IGN1/PWM4324Serial1_TX_LOG25INJLS11/PWM1926BATT+27BATT+28BATT-29BATT+30SerialDBG_TX_LOG31DOUT2/PWM5232Serial1_RX_LOG33ETHTRX-134INJLS12/PWM2035BATT+36BATT+37BATT-38BATT+39DOUT1/PWM5140DOUT4/PWM5441ETHTRX+142ETHTX-143INJHS3/PWM544BATT+45HBB2/PWM3646BATT-47CANH_CTRL-LOG48DOUT3/PWM5349HBA1/PWM3350ETHTX+151INJLS3/PWM652HBB2/PWM3653HBA2/PWM3554BATT-55CANL_CTRL-LOG56HBB1/PWM3457HBA1/PWM3358INJLS9/PWM1759INJLS10/PWM1860HBA2/PWM3561BATT-62INJLS14/PWM2263HBB1/PWM3464INJLS15/PWM2365INJLS16/PWM2466INJLS13/PWM21
C2 — AS218-35PA-943B; mating AS618-35SA
PinSignal in source1ECATTX+2ECATRX-3ETH1000+44EXTPSU115EXTPSU126ECATTX-7ECATRX+8ETH1000-49ETH1000-310EXTPSU1311EXTPSU1412CANL_LOG13CANH_LOG14N/C15ETH1000+316ETH1000+217EXTPSU418EXTPSU219DOUT8/PWM5820DOUT6/PWM5621DOUT7/PWM5722N/C23ETH1000-224ETH1000+125EXTPSU326EXTPSU127AIN228AIN129AIN430DOUT5/PWM5531Not labelled in source32ETH1000-133DIN1/AIN34TCNEG235LamTrim236LamTrim137AIN538AIN639AIN340Not labelled in source41DIN2/AIN42LAMVS143TCPOS244TCPOS145DIN6/AIN46N / C47KNOCK148N / C49LAMIP150KNOCK251TCNEG152DIN7/AIN53DIN4/AIN54Not labelled in source55DIN5/AIN56DIN3/AIN57LAMVS258DIN8/AIN59Not labelled in source60PROT-GND261N / C62CRANK163LAMIP264PROT-GND165PROT-GND266CAM
C3 — AS218-35SN-943B; mating AS618-35PN
PinSignal in source1Not labelled in source2EXTPSU193ETH2_TX- /FM14AIN HS1/CPM15Not labelled in source6EXTPSU217ETH2_TX+ /FP18ETH2_RX- /FM29ETH2_RX+ /FP210AIN HS3/CPM311N/C12Not labelled in source13N/C14N/C15CANL_CTRL16CANH_CTRL17AIN HS4/CPM418AIN HS2/CPM219N/C20Not labelled in source21PT1000 1 / AIN22AIN1823AIN1324AIN1425N/C26Not labelled in source27Not labelled in source28Not labelled in source29Not labelled in source30N/C31AIN1732AIN1133AIN1234N/C35N/C36Not labelled in source37Not labelled in source38Not labelled in source39AIN1640DIN HS2/AIN41AIN942AIN1043N/C44PROT-GND345AIN846AIN1947AIN1548DIN HS1/AIN49EXTPSU1850EXTPSU1651PROT-GND352PROT-GND453AIN754N/C55N/C56ScopeOut257ScopeOut158PROT-GND459EXTPSU560EXTPSU661EXTPSU762EXTPSU1563EXTPSU1764EXTPSU865EXTPSU966EXTPSU10
C4 — AS218-35SA-943B; mating AS618-35PA
PinSignal in source1N/C2IGN5/PWM473IGN6/PWM484N/C5N/C6IGN5/PWM477IGN6/PWM488IGN7/PWM499IGN8/PWM5010N/C11BATT-12BATT-13BATT-14IGN7/PWM4915IGN8/PWM5016N/C17N/C18Not labelled in source19BATT-20LIN121Not labelled in source22Not labelled in source23N/C24Not labelled in source25N/C26BATT-27BATT-28LIN229Not labelled in source30Not labelled in source31N/C32N/C33EXTPSU2034INJLS19 / PWM2735BATT+36N/C37Not labelled in source38Not labelled in source39N/C40N/C41N/C42EXTPSU2243INJLS20 / PWM2844BATT+45BATT+46HBB3/PWM3847N/C48Not labelled in source49PROT-GND550PROT-GND551N/C52BATT+53HBB3/PWM3854HBA3/PWM3755Not labelled in source56PROT-GND657PROT-GND658N/C59INJLS17 / PWM2560HBA3/PWM3761Not labelled in source62N/C63N/C64INJLS18 / PWM2665N/C66N/C
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 4: Cosworth Antares 4Manufacturer product photograph: Cosworth. Permission to republish confirmed by the user.
The Antares 4 is a Cosworth Antares family ECU and vehicle controller. Cosworth describes it as a lower-cost entry in its Antares range while retaining data-logging and powertrain-control functions. Cosworth product information.
Manufacturer product specification
Cosworth's Antares 4 product page describes optimisation for 4-cylinder GDI or 8-cylinder port injection; it lists 3 CAN ports, 4 GB logging, two onboard lambda inputs, two knock inputs and three H-bridge pairs. Maximum counts include alternative functions, so they are not necessarily simultaneously available. Confirm hardware and enabled strategy against the current build.
A separate family comparison leaflet gives different cylinder/driver figures from the product page; these should not be reconciled without revision-specific confirmation. Use the exact build sheet and software from Cosworth for the installation.
Identification and control
Confirm the exact ordered configuration and obtain the matching connector and calibration documents from Cosworth. Antares family feature headlines do not establish that every feature is enabled on this particular unit. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
The tables list all 66 numbered positions for each of four connectors from Cosworth’s Antares 4 product sheet, cover version 0.3. Signal names and connector part numbers follow that sheet; “not labelled in source” denotes an empty signal cell and must not be read as a confirmed unused pin. Where the sheet shows two pins for one signal, both are listed individually. Consult the source for the paired-pin notation, wiring, current limits, optional functions, grounds and orientation.
Document identification discrepancy: the cover and ordering table identify Antares 4 and product 01E-501154, but the final page identifies document 29E-501156-P, revision 1.0; 01E-501156 is identified elsewhere by Cosworth as Antares 6. The cover and final page also show different version numbers. Confirm the document and pin assignments for the exact unit directly with Cosworth before wiring.
C1 — AS218-35PN-943B; mating AS618-35SN
Pin
Signal in source
1
INJLS2/PWM4
2
INJHS2/PWM3
3
IGN4/PWM46
4
INJLS1/PWM2
5
INJHS1/PWM1
6
BATT-
7
IGN4/PWM46
8
IGN3/PWM45
9
IGN2/PWM44
10
INJHS4/PWM7
11
BATT-
12
BATT-
13
Serial2_TX_CTRL
14
IGN3/PWM45
15
IGN2/PWM44
16
IGN1/PWM43
17
INJLS4/PWM8
18
BATT+
19
BATT-
20
BATT-
21
Serial2_RX_CTRL
22
SerialDBG_RX_LOG
23
IGN1/PWM43
24
Serial1_TX_LOG
25
INJLS11/PWM19
26
BATT+
27
BATT+
28
BATT-
29
BATT+
30
SerialDBG_TX_LOG
31
DOUT2/PWM52
32
Serial1_RX_LOG
33
ETHTRX-1
34
INJLS12/PWM20
35
BATT+
36
BATT+
37
BATT-
38
BATT+
39
DOUT1/PWM51
40
DOUT4/PWM54
41
ETHTRX+1
42
ETHTX-1
43
INJHS3/PWM5
44
BATT+
45
HBB2/PWM36
46
BATT-
47
CANH_CTRL-LOG
48
DOUT3/PWM53
49
HBA1/PWM33
50
ETHTX+1
51
INJLS3/PWM6
52
HBB2/PWM36
53
HBA2/PWM35
54
BATT-
55
CANL_CTRL-LOG
56
HBB1/PWM34
57
HBA1/PWM33
58
INJLS9/PWM17
59
INJLS10/PWM18
60
HBA2/PWM35
61
BATT-
62
INJLS14/PWM22
63
HBB1/PWM34
64
INJLS15/PWM23
65
INJLS16/PWM24
66
INJLS13/PWM21
C2 — AS218-35PA-943B; mating AS618-35SA
Pin
Signal in source
1
ECATTX+
2
ECATRX-
3
ETH1000+4
4
EXTPSU11
5
EXTPSU12
6
ECATTX-
7
ECATRX+
8
ETH1000-4
9
ETH1000-3
10
EXTPSU13
11
EXTPSU14
12
CANL_LOG
13
CANH_LOG
14
N/C
15
ETH1000+3
16
ETH1000+2
17
EXTPSU4
18
EXTPSU2
19
DOUT8/PWM58
20
DOUT6/PWM56
21
DOUT7/PWM57
22
N/C
23
ETH1000-2
24
ETH1000+1
25
EXTPSU3
26
EXTPSU1
27
AIN2
28
AIN1
29
AIN4
30
DOUT5/PWM55
31
Not labelled in source
32
ETH1000-1
33
DIN1/AIN
34
TCNEG2
35
LamTrim2
36
LamTrim1
37
AIN5
38
AIN6
39
AIN3
40
Not labelled in source
41
DIN2/AIN
42
LAMVS1
43
TCPOS2
44
TCPOS1
45
DIN6/AIN
46
N / C
47
KNOCK1
48
N / C
49
LAMIP1
50
KNOCK2
51
TCNEG1
52
DIN7/AIN
53
DIN4/AIN
54
Not labelled in source
55
DIN5/AIN
56
DIN3/AIN
57
LAMVS2
58
DIN8/AIN
59
Not labelled in source
60
PROT-GND2
61
N / C
62
CRANK1
63
LAMIP2
64
PROT-GND1
65
PROT-GND2
66
CAM
C3 — AS218-35SN-943B; mating AS618-35PN
Pin
Signal in source
1
Not labelled in source
2
EXTPSU19
3
ETH2_TX- /FM1
4
AIN HS1/CPM1
5
Not labelled in source
6
EXTPSU21
7
ETH2_TX+ /FP1
8
ETH2_RX- /FM2
9
ETH2_RX+ /FP2
10
AIN HS3/CPM3
11
N/C
12
Not labelled in source
13
N/C
14
N/C
15
CANL_CTRL
16
CANH_CTRL
17
AIN HS4/CPM4
18
AIN HS2/CPM2
19
N/C
20
Not labelled in source
21
PT1000 1 / AIN
22
AIN18
23
AIN13
24
AIN14
25
N/C
26
Not labelled in source
27
Not labelled in source
28
Not labelled in source
29
Not labelled in source
30
N/C
31
AIN17
32
AIN11
33
AIN12
34
N/C
35
N/C
36
Not labelled in source
37
Not labelled in source
38
Not labelled in source
39
AIN16
40
DIN HS2/AIN
41
AIN9
42
AIN10
43
N/C
44
PROT-GND3
45
AIN8
46
AIN19
47
AIN15
48
DIN HS1/AIN
49
EXTPSU18
50
EXTPSU16
51
PROT-GND3
52
PROT-GND4
53
AIN7
54
N/C
55
N/C
56
ScopeOut2
57
ScopeOut1
58
PROT-GND4
59
EXTPSU5
60
EXTPSU6
61
EXTPSU7
62
EXTPSU15
63
EXTPSU17
64
EXTPSU8
65
EXTPSU9
66
EXTPSU10
C4 — AS218-35SA-943B; mating AS618-35PA
Pin
Signal in source
1
N/C
2
IGN5/PWM47
3
IGN6/PWM48
4
N/C
5
N/C
6
IGN5/PWM47
7
IGN6/PWM48
8
IGN7/PWM49
9
IGN8/PWM50
10
N/C
11
BATT-
12
BATT-
13
BATT-
14
IGN7/PWM49
15
IGN8/PWM50
16
N/C
17
N/C
18
Not labelled in source
19
BATT-
20
LIN1
21
Not labelled in source
22
Not labelled in source
23
N/C
24
Not labelled in source
25
N/C
26
BATT-
27
BATT-
28
LIN2
29
Not labelled in source
30
Not labelled in source
31
N/C
32
N/C
33
EXTPSU20
34
INJLS19 / PWM27
35
BATT+
36
N/C
37
Not labelled in source
38
Not labelled in source
39
N/C
40
N/C
41
N/C
42
EXTPSU22
43
INJLS20 / PWM28
44
BATT+
45
BATT+
46
HBB3/PWM38
47
N/C
48
Not labelled in source
49
PROT-GND5
50
PROT-GND5
51
N/C
52
BATT+
53
HBB3/PWM38
54
HBA3/PWM37
55
Not labelled in source
56
PROT-GND6
57
PROT-GND6
58
N/C
59
INJLS17 / PWM25
60
HBA3/PWM37
61
Not labelled in source
62
N/C
63
N/C
64
INJLS18 / PWM26
65
N/C
66
N/C
Revision 4: Cosworth Antares 4Manufacturer product photograph: Cosworth. Permission to republish confirmed by the user.
The Antares 4 is a Cosworth Antares family ECU and vehicle controller. Cosworth describes it as a lower-cost entry in its Antares range while retaining data-logging and powertrain-control functions. Cosworth product information.
Manufacturer product specification
Cosworth's Antares 4 product page describes optimisation for 4-cylinder GDI or 8-cylinder port injection; it lists 3 CAN ports, 4 GB logging, two onboard lambda inputs, two knock inputs and three H-bridge pairs. Maximum counts include alternative functions, so they are not necessarily simultaneously available. Confirm hardware and enabled strategy against the current build.
A separate family comparison leaflet gives different cylinder/driver figures from the product page; these should not be reconciled without revision-specific confirmation. Use the exact build sheet and software from Cosworth for the installation.
Identification and control
Confirm the exact ordered configuration and obtain the matching connector and calibration documents from Cosworth. Antares family feature headlines do not establish that every feature is enabled on this particular unit. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
The tables list all 66 numbered positions for each of four connectors from Cosworth’s Antares 4 product sheet, cover version 0.3. Signal names and connector part numbers follow that sheet; “not labelled in source” denotes an empty signal cell and must not be read as a confirmed unused pin. Where the sheet shows two pins for one signal, both are listed individually. Consult the source for the paired-pin notation, wiring, current limits, optional functions, grounds and orientation.
Document identification discrepancy: the cover and ordering table identify Antares 4 and product 01E-501154, but the final page identifies document 29E-501156-P, revision 1.0; 01E-501156 is identified elsewhere by Cosworth as Antares 6. The cover and final page also show different version numbers. Confirm the document and pin assignments for the exact unit directly with Cosworth before wiring.