Page organisation in this revision
- Page type
- Reference hub
- Subject
- Engine ECU
- Parent
- GEMS Performance Electronics standalone ECUs
- Applies to
- No ECU-specific applicability
- Tool groups
- None
- Manufacturers
- None
Changes from revision 2 to revision 3
Removed text is struck through; added text is highlighted.
GEMS EM36: A historical GEMS ECU identity listed in GWv4 connection documentation. Manufacturer source.
Hardware and control
The manufacturer software manual names EM36 in its legacy connection settings. A GEMS forum discussion also names EM40 alongside it, but that discussion does not establish interchangeable hardware or connector functions. Identify the ECU name, version and wiring for the specific unit. GEMS model information.
GEMS systems use GWv4 configuration, with the required ECU definition and licence; software options and custom builds can differ. Record the label, hardware and firmware and confirm connected devices against the matching documentation. GWv4 manual.
Connector and wiring
The GEMS EM36 Operation Manual, © 2008, pages 110–112 gives the 36-way loom-connector schedule below. This is a third-party-hosted copy of the manufacturer's manual; use its loom-end view and wiring notes, and confirm board and calibration with GEMS. Many outputs are configurable, shared, or jumper-dependent. An engineer on GEMS' support forum separately identifies model-specific pin-assignment examples.
PinFunction in manualSource notationA1IGN1TOC1, TO220A2IGN6 / FUEL12TOC6, TO220A3FUEL8PW8 (PW1678)A4Power inputADR 07A5Power returnA6Sensor returnA7CrankTINC IC0, ADR 12, T1A8Timing groundA9CoolantADR 05A10MAP2ADR 06A11CamTINC PH0, ADR 13, also T2 IC7A12IGN2TOC2, TO220B1IGN4 / FUEL10TOC4, TO220B2IGN5 / FUEL11TOC5, TO220B3FUEL6PW6 (PW1656)B4FUEL1PW1B5FUEL5PW5B6MAP1LS PH3, ADR 01B7Power returnB8FUEL7TIN PJ3, PW7, ADR 14, T3B9Air temperatureADR 04B10Knock5–15 kHz, ADR 02, ADCR16B11OX2ADR 10B12IGN3 / FUEL9TOC3, TO220C1Sensor powerHS2 PE7, 12 VC2FUEL4HB PW4 (PW1634), half-bridgeC3FUEL2HB PW2 (PW1612), half-bridgeC4Main relayTOC7, also T2C5HS1PE3C6FUEL3PW3C7OX1ADR 03C8TPSADR 00C9Sensor powerADR 17, 5 VC10Timing inputTIN PH7, ADR 15, T4IC11Alternate 12 V powerPE0, ADR 17C12TachometerLS PE2
Nine-way communications socket
The same manual lists optional CAN and RS-422 assignments on the nine-way D-type socket. Options depend on the ECU build and must not be assumed fitted.
PinFunction1CAN L (optional)2TX, RS-232C3RX, RS-232C4BUSB (optional RS-422)5Ground6CAN H (optional)7BUSZ (optional RS-422)8BUSY (optional RS-422)9BUSA (optional RS-422)
Structured pinoutA structured pin index and redrawn diagram for the 36-way loom connector and the 9-way communications socket are in GEMS EM36 connector pinout.Not establishedThe microcontroller used in the EM36 is not named in the GEMS documentation available for this page.Further references
GEMS EM36 manufacturer sourceGEMS software and downloadsGEMS manufacturer overview
Sources reviewed 17 November 2026.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 2: GEMS EM36
GEMS EM36: A historical GEMS ECU identity listed in GWv4 connection documentation. Manufacturer source.
Hardware and control
The manufacturer software manual names EM36 in its legacy connection settings. A GEMS forum discussion also names EM40 alongside it, but that discussion does not establish interchangeable hardware or connector functions. Identify the ECU name, version and wiring for the specific unit. GEMS model information.
GEMS systems use GWv4 configuration, with the required ECU definition and licence; software options and custom builds can differ. Record the label, hardware and firmware and confirm connected devices against the matching documentation. GWv4 manual.
Connector and wiring
The GEMS EM36 Operation Manual, © 2008, pages 110–112 gives the 36-way loom-connector schedule below. This is a third-party-hosted copy of the manufacturer's manual; use its loom-end view and wiring notes, and confirm board and calibration with GEMS. Many outputs are configurable, shared, or jumper-dependent. An engineer on GEMS' support forum separately identifies model-specific pin-assignment examples.
| Pin | Function in manual | Source notation |
|---|
| A1 | IGN1 | TOC1, TO220 |
| A2 | IGN6 / FUEL12 | TOC6, TO220 |
| A3 | FUEL8 | PW8 (PW1678) |
| A4 | Power input | ADR 07 |
| A5 | Power return | |
| A6 | Sensor return | |
| A7 | Crank | TINC IC0, ADR 12, T1 |
| A8 | Timing ground | |
| A9 | Coolant | ADR 05 |
| A10 | MAP2 | ADR 06 |
| A11 | Cam | TINC PH0, ADR 13, also T2 IC7 |
| A12 | IGN2 | TOC2, TO220 |
| B1 | IGN4 / FUEL10 | TOC4, TO220 |
| B2 | IGN5 / FUEL11 | TOC5, TO220 |
| B3 | FUEL6 | PW6 (PW1656) |
| B4 | FUEL1 | PW1 |
| B5 | FUEL5 | PW5 |
| B6 | MAP1 | LS PH3, ADR 01 |
| B7 | Power return | |
| B8 | FUEL7 | TIN PJ3, PW7, ADR 14, T3 |
| B9 | Air temperature | ADR 04 |
| B10 | Knock | 5–15 kHz, ADR 02, ADCR16 |
| B11 | OX2 | ADR 10 |
| B12 | IGN3 / FUEL9 | TOC3, TO220 |
| C1 | Sensor power | HS2 PE7, 12 V |
| C2 | FUEL4 | HB PW4 (PW1634), half-bridge |
| C3 | FUEL2 | HB PW2 (PW1612), half-bridge |
| C4 | Main relay | TOC7, also T2 |
| C5 | HS1 | PE3 |
| C6 | FUEL3 | PW3 |
| C7 | OX1 | ADR 03 |
| C8 | TPS | ADR 00 |
| C9 | Sensor power | ADR 17, 5 V |
| C10 | Timing input | TIN PH7, ADR 15, T4I |
| C11 | Alternate 12 V power | PE0, ADR 17 |
| C12 | Tachometer | LS PE2 |
Nine-way communications socket
The same manual lists optional CAN and RS-422 assignments on the nine-way D-type socket. Options depend on the ECU build and must not be assumed fitted.
| Pin | Function |
|---|
| 1 | CAN L (optional) |
| 2 | TX, RS-232C |
| 3 | RX, RS-232C |
| 4 | BUSB (optional RS-422) |
| 5 | Ground |
| 6 | CAN H (optional) |
| 7 | BUSZ (optional RS-422) |
| 8 | BUSY (optional RS-422) |
| 9 | BUSA (optional RS-422) |
Further references
Sources reviewed 17 November 2026.
Revision 3: GEMS EM36
GEMS EM36: A historical GEMS ECU identity listed in GWv4 connection documentation. Manufacturer source.
Hardware and control
The manufacturer software manual names EM36 in its legacy connection settings. A GEMS forum discussion also names EM40 alongside it, but that discussion does not establish interchangeable hardware or connector functions. Identify the ECU name, version and wiring for the specific unit. GEMS model information.
GEMS systems use GWv4 configuration, with the required ECU definition and licence; software options and custom builds can differ. Record the label, hardware and firmware and confirm connected devices against the matching documentation. GWv4 manual.
Connector and wiring
The GEMS EM36 Operation Manual, © 2008, pages 110–112 gives the 36-way loom-connector schedule below. This is a third-party-hosted copy of the manufacturer's manual; use its loom-end view and wiring notes, and confirm board and calibration with GEMS. Many outputs are configurable, shared, or jumper-dependent. An engineer on GEMS' support forum separately identifies model-specific pin-assignment examples.
| Pin | Function in manual | Source notation |
|---|
| A1 | IGN1 | TOC1, TO220 |
| A2 | IGN6 / FUEL12 | TOC6, TO220 |
| A3 | FUEL8 | PW8 (PW1678) |
| A4 | Power input | ADR 07 |
| A5 | Power return | |
| A6 | Sensor return | |
| A7 | Crank | TINC IC0, ADR 12, T1 |
| A8 | Timing ground | |
| A9 | Coolant | ADR 05 |
| A10 | MAP2 | ADR 06 |
| A11 | Cam | TINC PH0, ADR 13, also T2 IC7 |
| A12 | IGN2 | TOC2, TO220 |
| B1 | IGN4 / FUEL10 | TOC4, TO220 |
| B2 | IGN5 / FUEL11 | TOC5, TO220 |
| B3 | FUEL6 | PW6 (PW1656) |
| B4 | FUEL1 | PW1 |
| B5 | FUEL5 | PW5 |
| B6 | MAP1 | LS PH3, ADR 01 |
| B7 | Power return | |
| B8 | FUEL7 | TIN PJ3, PW7, ADR 14, T3 |
| B9 | Air temperature | ADR 04 |
| B10 | Knock | 5–15 kHz, ADR 02, ADCR16 |
| B11 | OX2 | ADR 10 |
| B12 | IGN3 / FUEL9 | TOC3, TO220 |
| C1 | Sensor power | HS2 PE7, 12 V |
| C2 | FUEL4 | HB PW4 (PW1634), half-bridge |
| C3 | FUEL2 | HB PW2 (PW1612), half-bridge |
| C4 | Main relay | TOC7, also T2 |
| C5 | HS1 | PE3 |
| C6 | FUEL3 | PW3 |
| C7 | OX1 | ADR 03 |
| C8 | TPS | ADR 00 |
| C9 | Sensor power | ADR 17, 5 V |
| C10 | Timing input | TIN PH7, ADR 15, T4I |
| C11 | Alternate 12 V power | PE0, ADR 17 |
| C12 | Tachometer | LS PE2 |
Nine-way communications socket
The same manual lists optional CAN and RS-422 assignments on the nine-way D-type socket. Options depend on the ECU build and must not be assumed fitted.
| Pin | Function |
|---|
| 1 | CAN L (optional) |
| 2 | TX, RS-232C |
| 3 | RX, RS-232C |
| 4 | BUSB (optional RS-422) |
| 5 | Ground |
| 6 | CAN H (optional) |
| 7 | BUSZ (optional RS-422) |
| 8 | BUSY (optional RS-422) |
| 9 | BUSA (optional RS-422) |
Structured pinout
A structured pin index and redrawn diagram for the 36-way loom connector and the 9-way communications socket are in GEMS EM36 connector pinout.
Not established
The microcontroller used in the EM36 is not named in the GEMS documentation available for this page.
Further references
Sources reviewed 17 November 2026.