FuelTech FT600
FT600. Image: FuelTech media kit; editorial and web use permitted.

FuelTech FT600 is a PowerFT engine-management unit. PowerFT ECU with 20 configurable inputs and 32 outputs, including support for up to 16 injector channels as configured. It integrates a display and data logging. FuelTech model documentation · FuelTech range comparison.

Identification and software

Record the exact model, serial, harness, firmware and configured outputs; similarly named FT models may use different connectors and functions. Tuning software: FTManager. FuelTech software and compatibility.

Wiring and pinout

Use the model-specific manual and the current FuelTech manuals index for connector view, cavity numbering, fuse values, sensor grounds and injector-driver limits. The manufacturer wiring archive contains installation-specific examples; match the exact ECU and harness before wiring. Pin functions depend on the model, hardware and configured output.

See FuelTech engine-management family for other models and company background. FuelTech is based in Brazil and has a US operation in Georgia. Sources reviewed 17 November 2026.

FT600 ECU connector pin assignments

The FuelTech FT600 manual, sections 4.3 and 4.4, identifies two 34-way ECU connectors. The listed sensor and output functions are configurable; use the exact revision and check the connector view, driver ratings, protection and ground routing in the original. The magnetic trigger references are not generic Hall sensor grounds.

Connector A — 34 way

PinFunction and harness wire
1Blue output #1 (blue #1)
2Blue output #2 (blue #2)
3Blue output #3 (blue #3)
4Blue output #4 (blue #4)
5Blue output #5 (blue #5)
6Blue output #6 (blue #6)
7Blue output #7 (blue #7)
8Blue output #8 (blue #8)
9Blue output #9 (blue #9)
10Blue output #10 (blue #10)
11Blue output #11 (blue #11)
12Blue output #12 (blue #12)
13Blue output #13 (blue #13)
14Blue output #14 (blue #14)
15Blue output #15 (blue #15)
16Blue output #16 (blue #16)
17Power ground (black/white)
18Gray output #1 (gray #1)
19Gray output #2 (gray #2)
20Gray output #3 (gray #3)
21Gray output #4 (gray #4)
22Gray output #5 (gray #5)
23Gray output #6 (gray #6)
24Gray output #7 (gray #7)
25Gray output #8 (gray #8)
26Yellow output #1 (yellow #1)
27Yellow output #2 (yellow #2)
28Yellow output #3 (yellow #3)
29Yellow output #4 (yellow #4)
30Yellow output #5 (yellow #5)
31Yellow output #6 (yellow #6)
32Yellow output #7 (yellow #7)
33Yellow output #8 (yellow #8)
3412 V input from main relay (red)

Connector B — 34 way

PinFunction and harness wire
1RPM signal input (red)
2Magnetic RPM sensor reference (white)
3Cam sync signal input (red)
4Cam sync reference input (white)
5White input #1
6White input #2
7White input #3
8White input #4
9White input #5
10Battery negative (black)
11CAN A low (yellow/blue)
12CAN A high (white/red)
13White input #6
14White input #7
15White input #8
16White input #9
17White input #10
18Power ground (black/white)
19Power ground (black/white)
20CAN B high (white/red)
21White input #11
22White input #12
23White input #13
24White input #14
25White input #15
2612 V input from main relay (red)
275 V sensor supply (green/red)
28CAN B low (yellow/blue)
29Sensor ground (green/black)
30White input #16
31White input #17
32White input #18
33White input #19 / Power Shift positive
34White input #20 / Power Shift negative

Use the manual's power, grounding, relay and sensor instructions; power-ground and sensor-ground circuits have different functions. The optional Power Shift uses input channels 19 and 20 on this model.