Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Reference hub
Subject
Engine ECU
Parent
Emtron standalone ECUs
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None
Emtron KV16 ECU
Emtron KV16 product image, courtesy of Emtron; reproduced with permission.

Emtron KV16 is a programmable standalone ECU from Emtron Australia. Sixteen fuel and twelve sequential ignition channels are listed. KV16 Rev2 uses four connector housings and differs from KV8/KV12 in populated outputs. Emtron KV16 datasheet.

Identification and configuration

Record the ECU model, serial, board revision and loaded firmware. The Emtune calibration determines the use of configurable inputs and outputs; electrical limits, ignition driver type, injector impedance and wired supplies must be checked for the actual unit. Emtron engine-management manual.

Connector pinouts — revision 2

These tables reproduce the positions in Emtron's KV16 Rev2 pinout. The source diagrams are viewed looking into the ECU connector. NC is the manufacturer's unconnected designation. Verify connector keying, revision, power, grounds and all limits in the original before wiring; assignments differ between models and hardware revisions.

Connector A

PinChannel Name
A1Injection Channel 9
A2Injection Channel 10
A3Injection Channel 11
A4Injection Channel 12
A5Injection Channel 13
A6Injection Channel 14
A7Injection Channel 15
A8Ignition Channel 9
A9Ignition Channel 10
A10Lambda 1 Heater -
A11Lambda 2 Heater -
A12Injection Channel 16
A13ECU Ground
A14Ignition Channel 11
A15Ignition Channel 12
A16Lambda 1 Heater +
A17Lambda 2 Heater +
A18Lambda 1 Nernst Cell (Vs)
A19ECU Ground
A20Lambda 2 Cal Resistor (CalR)
A21Lambda 2 Nernst Cell (Vs)
A22Lambda 2 Pump Cell (Ip)
A23Lambda 2 Virtual Ground (VGnd)
A24Lambda 1 Cal Resistor (CalR)
A25Lambda 1 Pump Cell (Ip)
A26Lambda 1 Virtual Ground (VGnd)

Connector B

PinChannel NamePinChannel Name
B1Injection Channel 1B18Auxiliary Output 9
B2Injection Channel 2B19Auxiliary Output 10
B3Injection Channel 3B20Auxiliary Output 11
B4Injection Channel 4B21Auxiliary Output 12
B5Injection Channel 5B22Auxiliary Output 13
B6Injection Channel 6B23Auxiliary Output 14
B7Injection Channel 7B24Auxiliary Output 15
B8Injection Channel 8B25Auxiliary Output 16
B9ECU GroundB26Ignition Channel 1
B10Auxiliary Output 1B27Ignition Channel 2
B11Auxiliary Output 2B28Ignition Channel 3
B12Auxiliary Output 3B29Ignition Channel 4
B13Auxiliary Output 4B30Ignition Channel 5
B14Auxiliary Output 5B31Ignition Channel 6
B15Auxiliary Output 6B32Ignition Channel 7
B16Auxiliary Output 7B33Ignition Channel 8
B17Auxiliary Output 8B34ECU Ground

Connector C

PinChannel NamePinChannel Name
C1ECU GroundC18Digital Input 9
C2Analog Input Channel 1C19Digital Input 10
C3Analog Input Channel 2C20Digital Input 11
C4Analog Input Channel 3C21Digital Input 12
C5Analog Input Channel 4C22Digital Input 13
C6Analog Input Channel 5C23Digital Input 14
C7Analog Input Channel 6C24Analog Input Channel 16
C8Analog Input Channel 7C25Analog Sensor 0V Reference
C9Analog Input Channel 8C26ECU Ground
C10Analog Input Channel 9C27Digital Input 1
C11Analog Input Channel 10C28Digital Input 2
C12Analog Input Channel 11C29Digital Input 3
C13Analog Input Channel 12C30Digital Input 4
C14Analog Input Channel 13C31Digital Input 5
C15Analog Input Channel 14C32Digital Input 6
C16Analog Input Channel 15C33Digital Input 7
C17Analog Sensor 0V ReferenceC34Digital Input 8

Connector D

PinChannel Name
D1ECU 14V Supply
D2Auxiliary Output 13-16 14V Supply
D3Sensor Supply 8V
D4Crank Index Sensor +
D5Crank Index Sensor -
D6Sync Sensor +
D7Sync Sensor -
D8CAN 1H
D9EFI Relay Output (Low Side 200mA)
D10CAN 2H
D11Knock 1 +
D12Knock 1 -
D13Shield (Crank/Cam/ Knock)
D14CAN 1L
D15Ignition Switch Input
D16CAN 2L
D17Knock 2 +
D18Knock 2 -
D19Analog Output (0.0 - 5.0V)
D20Auxiliary Output 9-12 14V Supply
D21Sensor Supply Vref1: 5.0V
D22Sensor Supply Vref2: 5.0V
D23Ethernet Tx +
D24Ethernet Tx -
D25Ethernet Rx +
D26Ethernet Rx -

Sensor 0 V references and main ECU grounds have distinct wiring requirements. H-bridge supplies and relay control require the installation described in the manufacturer's power-distribution guide. See Emtron wiring index and revision-specific diagrams.

Documentation and setup