Page type
Reference hub
Subject
Engine ECU
Parent
ECUMaster standalone ECUs
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None
EMU Pro-8 ECU
EMU Pro-8. Manufacturer product image: source; reproduced with permission.

Pro-8 is the smaller ECU in the EMU Pro range, aimed at up to eight-cylinder engines. ECUMaster lists eight peak-and-hold injector outputs, eight software-selectable active or passive ignition outputs, 12 low-side auxiliary outputs, three full H-bridges, two LSU 4.9 controllers, two drive-by-wire controllers, two CAN buses and one LIN bus. The IP65 enclosure measures 165 × 95 × 38 mm. Direct-injection engines need the separate GDI Driver. Manufacturer product specification · Manufacturer comparison.

Connector pinout and wiring

The linked v1.0 pinout specifies three Superseal 1.0 mating housings A 4-1437290-1, B 1473416-1 and C 4-1437290-0. CAN1 serves PC communications and requires external termination; USB is for a flash logging drive. Use the exact PDF drawings for cavity numbers, orientation and current limits. Exact-model manufacturer pinout.

Software and installation

Record the ECU serial, firmware, software and project versions and confirm assigned outputs and trigger inputs before connecting loads. The manufacturer downloads contain current software, manuals and supported base maps. Base maps do not establish the correct pinout for a particular vehicle. Compare with the ECUMaster family guide.

Connector pin tables

The tables transcribe ECUMaster Pro-8 pinout v1.0. Use the numbered manufacturer connector drawings and mating-housing keys to establish orientation; these tables describe ECU connector positions, not sensor-side terminal numbers. Configurable and shared functions depend on software setup. Refer to the source for protection, currents, grounds, termination and sensor-wiring conditions before use.

Connector A

PinManufacturer function
A1Ignition 8
A2Injector 1
A3Injector 2
A4Injector 3
A5Injector 4
A6Injector 5
A7Injector 6
A8Injector 7
A9Injector 8
A10Ignition 7
A11Power ground
A12+5 V source A
A13Digital 2
A14Digital 4
A15Digital 8
A16Digital 6 (turboshaft)
A17Power ground
A18Ignition 6
A19Power ground
A20Digital ground
A21Digital 1 (crank)
A22Digital 3
A23Digital 7
A24Digital 5 (turboshaft)
A25Auxiliary 9
A26Ignition 5
A27Ignition 4
A28Ignition 3
A29Ignition 2
A30Ignition 1
A31CAN 1 high (PC)
A32CAN 1 low (PC)
A33CAN 2 high
A34CAN 2 low

Connector B

PinManufacturer function
B1Auxiliary 1 (wideband heater option)
B2Auxiliary 2 (wideband heater option)
B3Auxiliary 3 (wideband heater option)
B4Auxiliary 4 (wideband heater option)
B5Auxiliary 5
B6Auxiliary 6
B7Auxiliary 7
B8+12 V supply
B9Digital ground (flash drive)
B10USB D− (flash drive)
B11USB D+ (flash drive)
B12+5 V source A (flash drive)
B13Auxiliary 8
B14+12 V supply
B15+12 V switched
B16Knock sensor 1
B17Knock sensor 2
B18Wideband 2 VGND (LSU 4.9)
B19Power ground
B20Wideband 1 Ip (LSU 4.9)
B21Wideband 1 Vs (LSU 4.9)
B22Wideband 1 Rcal (LSU 4.9)
B23Wideband 1 VGND (LSU 4.9)
B24Wideband 2 Ip (LSU 4.9)
B25Wideband 2 Vs (LSU 4.9)
B26Wideband 2 Rcal (LSU 4.9)

Connector C

PinManufacturer function
C1Auxiliary 10
C2Auxiliary 11
C3Auxiliary 12
C4Analogue 7
C5Analogue 10 (2.2 kΩ pull)
C6H-bridge 1A
C7H-bridge 2B
C8H-bridge 3A
C9H-bridge 2A
C10Analogue 1 (MAP)
C11Analogue 3
C12Analogue 5
C13Analogue 8
C14Analogue 11 (2.2 kΩ pull)
C15Analogue 13 (1 kΩ pull)
C16Analogue 15 (330 Ω pull)
C17H-bridge 3B
C18Analogue 2
C19Analogue 4
C20Analogue 6
C21Analogue 9 (2.2 kΩ pull)
C22Analogue 12 (2.2 kΩ pull)
C23Analogue 14 (1 kΩ pull)
C24Analogue 16 (100 Ω pull)
C25H-bridge 1B
C26LIN
C27+5 V source B
C28+5 V source B
C29Analogue ground
C30Power ground
C31Precision analogue 1
C32Precision analogue 2
C33Precision analogue 3
C34Precision analogue 4

CAN1 carries PC communications and has no internal terminator in the cited document. B9–B12 are the flash-drive connections; they are not the tuning PC connection. All named power and sensor grounds have the specific wiring requirements described by the manufacturer.