Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Reference hub
Subject
Engine ECU
Parent
Standalone ECUs
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None

Changes from revision 4 to revision 7

Removed text is struck through; added text is highlighted.

Delta 400. Image: Specialist Control Systems; source: SCS Delta ECU range. Reproduced with permission.

Individual model references

Delta 400Delta 700Delta 800Delta 880Delta 900Delta GDI4Delta GDI6

Specialist Control Systems produces the SCS Delta programmable ECU range. Hardware configuration, connector pinout and firmware must be matched to the exact unit. SXTune ECU technical reference and product photographs

Earlier SC model references

Hurricane — limited informationStormTyphoonTyphoon 2Storm 2TornadoTornado 2Tornado GDITyphoonTyphoon 2Storm 2TornadoTornado 2Tornado GDI

Earlier models lack complete confirmed pinouts here unless a source is explicitly linked. The manufacturer explains that the listed SC units are obsolete and that replacement ECU wiring requirements differ. SCS legacy and conversion guidance.

ECU families

Delta 400, 700 and 900: models with manufacturer connector documentation.Delta GDI6: direct-injection model with its own three-connector pinout.Delta 800, 880 and GDI4: earlier Delta units in the manufacturer wiring reference.Earlier SC systems: Typhoon, Typhoon 2, Storm, Storm 2, Tornado, Tornado 2, Tornado GDI and Hurricane. SCS identifies specified 2008–2015 units as unsupported; the precise model and replacement wiring requirements matter. SCS discontinued models · SCS base mapsSDI4: diesel ECU identified in AiM's SCS ECU communications reference.

This list records documented families and is not an exhaustive list of special editions or application-specific units.

Delta 400 connector A pinout

For Delta 400 only, connector A AMPSeal 776164-1. Refer to the manufacturer's Delta 400 pinout for diagram, terminals, current limits, fuse values and connection orientation. Functions shown include the manufacturer's typical assignments; configurable inputs and outputs depend on calibration.

PinFunctionA1Battery supplyA2Ignition switched supplyA3Power ground 1A4Low side output 1 / injector 1A5Low side output 2 / injector 2A6Low side output 3 / injector 3A7Low side output 4 / injector 4A8Crank/cam sensor groundA9Crank sensorA10Cam sensor 1A11Coolant temperatureA12Air temperatureA13Ignition 1A14Ignition 2A15Ignition 3A16Ignition 4A17Analogue input 1A18Cam 2 / wheel speedA19Analogue ground 1A20Lambda 1 inputA21CAN 1 highA22CAN 1 lowA23Low side output 5 / multifunction I/OA24Low side output 7 / main relay, PWM 1A25Low side output 8 / fuel pump relay, PWM 2A26Low side output 9 / PWM 3A27Low side output 10 / PWM 4A28Low side output 11 / tachoA29Low side output 6 / multifunction I/OA30Analogue ground 2A31NTC input 3A32Analogue input 2 / TPS 1A33Analogue input 3 / MAPA345 V sensor referenceA35Power ground 2

Model-specific diagrams and photos

Delta 700 pinoutDelta 900 pinoutDelta GDI6 pinoutSXTune wiring index: Delta and legacy modelsSXTune hardware reference and photographs

Common-rail dieselDelta Diesel covers SCS's diesel ECU family, including separate-driver and integrated four-cylinder configurations; supported engine packages and wiring vary by application. SCS diesel system overview.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 4: SCS Delta standalone ECUs
SCS Delta 400 ECU product brochure
Delta 400. Image: Specialist Control Systems; source: SCS Delta ECU range. Reproduced with permission.

Individual model references

Specialist Control Systems produces the SCS Delta programmable ECU range. Hardware configuration, connector pinout and firmware must be matched to the exact unit. SXTune ECU technical reference and product photographs

Earlier SC model references

Earlier models lack complete confirmed pinouts here unless a source is explicitly linked. The manufacturer explains that the listed SC units are obsolete and that replacement ECU wiring requirements differ. SCS legacy and conversion guidance.

ECU families

  • Delta 400, 700 and 900: models with manufacturer connector documentation.
  • Delta GDI6: direct-injection model with its own three-connector pinout.
  • Delta 800, 880 and GDI4: earlier Delta units in the manufacturer wiring reference.
  • Earlier SC systems: Typhoon, Typhoon 2, Storm, Storm 2, Tornado, Tornado 2, Tornado GDI and Hurricane. SCS identifies specified 2008–2015 units as unsupported; the precise model and replacement wiring requirements matter. SCS discontinued models · SCS base maps
  • SDI4: diesel ECU identified in AiM's SCS ECU communications reference.

This list records documented families and is not an exhaustive list of special editions or application-specific units.

Delta 400 connector A pinout

For Delta 400 only, connector A AMPSeal 776164-1. Refer to the manufacturer's Delta 400 pinout for diagram, terminals, current limits, fuse values and connection orientation. Functions shown include the manufacturer's typical assignments; configurable inputs and outputs depend on calibration.

PinFunction
A1Battery supply
A2Ignition switched supply
A3Power ground 1
A4Low side output 1 / injector 1
A5Low side output 2 / injector 2
A6Low side output 3 / injector 3
A7Low side output 4 / injector 4
A8Crank/cam sensor ground
A9Crank sensor
A10Cam sensor 1
A11Coolant temperature
A12Air temperature
A13Ignition 1
A14Ignition 2
A15Ignition 3
A16Ignition 4
A17Analogue input 1
A18Cam 2 / wheel speed
A19Analogue ground 1
A20Lambda 1 input
A21CAN 1 high
A22CAN 1 low
A23Low side output 5 / multifunction I/O
A24Low side output 7 / main relay, PWM 1
A25Low side output 8 / fuel pump relay, PWM 2
A26Low side output 9 / PWM 3
A27Low side output 10 / PWM 4
A28Low side output 11 / tacho
A29Low side output 6 / multifunction I/O
A30Analogue ground 2
A31NTC input 3
A32Analogue input 2 / TPS 1
A33Analogue input 3 / MAP
A345 V sensor reference
A35Power ground 2

Model-specific diagrams and photos

Revision 7: SCS Delta standalone ECUs
SCS Delta 400 ECU product brochure
Delta 400. Image: Specialist Control Systems; source: SCS Delta ECU range. Reproduced with permission.

Individual model references

Specialist Control Systems produces the SCS Delta programmable ECU range. Hardware configuration, connector pinout and firmware must be matched to the exact unit. SXTune ECU technical reference and product photographs

Earlier SC model references

Earlier models lack complete confirmed pinouts here unless a source is explicitly linked. The manufacturer explains that the listed SC units are obsolete and that replacement ECU wiring requirements differ. SCS legacy and conversion guidance.

ECU families

  • Delta 400, 700 and 900: models with manufacturer connector documentation.
  • Delta GDI6: direct-injection model with its own three-connector pinout.
  • Delta 800, 880 and GDI4: earlier Delta units in the manufacturer wiring reference.
  • Earlier SC systems: Typhoon, Typhoon 2, Storm, Storm 2, Tornado, Tornado 2, Tornado GDI and Hurricane. SCS identifies specified 2008–2015 units as unsupported; the precise model and replacement wiring requirements matter. SCS discontinued models · SCS base maps
  • SDI4: diesel ECU identified in AiM's SCS ECU communications reference.

This list records documented families and is not an exhaustive list of special editions or application-specific units.

Delta 400 connector A pinout

For Delta 400 only, connector A AMPSeal 776164-1. Refer to the manufacturer's Delta 400 pinout for diagram, terminals, current limits, fuse values and connection orientation. Functions shown include the manufacturer's typical assignments; configurable inputs and outputs depend on calibration.

PinFunction
A1Battery supply
A2Ignition switched supply
A3Power ground 1
A4Low side output 1 / injector 1
A5Low side output 2 / injector 2
A6Low side output 3 / injector 3
A7Low side output 4 / injector 4
A8Crank/cam sensor ground
A9Crank sensor
A10Cam sensor 1
A11Coolant temperature
A12Air temperature
A13Ignition 1
A14Ignition 2
A15Ignition 3
A16Ignition 4
A17Analogue input 1
A18Cam 2 / wheel speed
A19Analogue ground 1
A20Lambda 1 input
A21CAN 1 high
A22CAN 1 low
A23Low side output 5 / multifunction I/O
A24Low side output 7 / main relay, PWM 1
A25Low side output 8 / fuel pump relay, PWM 2
A26Low side output 9 / PWM 3
A27Low side output 10 / PWM 4
A28Low side output 11 / tacho
A29Low side output 6 / multifunction I/O
A30Analogue ground 2
A31NTC input 3
A32Analogue input 2 / TPS 1
A33Analogue input 3 / MAP
A345 V sensor reference
A35Power ground 2

Model-specific diagrams and photos

Common-rail diesel

Delta Diesel covers SCS's diesel ECU family, including separate-driver and integrated four-cylinder configurations; supported engine packages and wiring vary by application. SCS diesel system overview.