MaxxECU PRO — High-channel-count GEN1 ECU for up to twelve sequential cylinders, with sixteen injector drivers and twelve ignition outputs. MaxxECU product information.

Model identification and capabilities
The manufacturer lists 16 peak-and-hold injector outputs, dual wideband LSU 4.2/4.9 support, 12 type K/N EGT inputs, 16 extra 0–5 V inputs, six extra temperature inputs and dual electronic-throttle capability. Its built-in MAP sensor is rated 400 kPa absolute; Bluetooth, USB and CAN are provided. Manufacturer specification; MaxxECU model comparison.
| Sequential cylinders, maximum | 12 |
|---|---|
| Injector outputs | 16 peak-and-hold |
| Ignition outputs | 12 |
| Configuration | MTune; check the release appropriate to the ECU and hardware revision |
Identification and installation
Connector 4 has revision-dependent knock and sensor-ground assignments: MaxxECU documents knock inputs on REV10+ and different ground assignments on earlier units. Verify the serial and exact revision before connecting.
Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.
Connector and pinout
Selected connector 1 positions shared in the manufacturer’s GEN1 table; consult the PRO column and all connector diagrams for full details. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.
| Position | Manufacturer function | Notes |
|---|---|---|
| A1 | GPO 5 | |
| A2 | IGN 1 | |
| A3 | IGN 2 | |
| A4 | GPO 8/TACHO | 660ohm pullup |
| B1 | GPO 6 | |
| B2 | IGN 3 | |
| B3 | IGN 4 | |
| B4 | GPO 1 | |
| C1 | GPO 7 | |
| C2 | IGN 5 | |
| C3 | IGN 6 | |
| C4 | GPO 2 | |
| D1 | WBO2 Heater- | |
| D2 | IGN 7 | |
| D3 | IGN 8 | |
| D4 | GPO 3 | |
| E1 | CAN H | |
| E2 | CAN L | |
| E3 | GND Shield | |
| E4 | GPO 4 | |
| F1 | CLT | |
| F2 | IAT | |
| F3 | WBO2 VREF | |
| F4 | WBO2 VS | |
| G1 | +5V sensor supply | (peak 0.5A, max 150mA) |
| G2 | TPS/AIN | |
| G3 | WBO2 IP | |
| G4 | WBO2 RCAL | |
| H1 | Sensor GND | |
| H2 | Trigger GND | |
| H3 | TRIGGER | |
| H4 | HOME | |
| J1 | AIN 1 (Temperature) | |
| J2 | AIN 2 (Temperature) | |
| J3 | AIN 3 (0-5V) | |
| J4 | AIN 4 (0-5V) | |
| K1 | INJ 1 | |
| K2 | INJ 2 | |
| K3 | DIN/VR 1 | |
| K4 | DIN/VR 2 | |
| L1 | INJ 8 | |
| L2 | INJ 7 | |
| L3 | INJ 6 | |
| L4 | Engine GND | |
| M1 | INJ 3 | |
| M2 | INJ 4 | |
| M3 | INJ 5 | |
| M4 | +12V ECU power supply |