MaxxECU V1 — Discontinued first-generation MaxxECU, superseded by RACE according to the manufacturer. MaxxECU product information.

MaxxECU V1, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

V1 has eight peak-and-hold injector outputs and eight ignition outputs, supporting up to eight sequential cylinders or twelve with wasted spark. The manufacturer lists eight EGT inputs, built-in wideband and a 400 kPa MAP sensor. Rev 6 raised injector output capability; Rev 7 added logging and digital-input changes; Rev 9 added LSU 4.9 support. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum8Injector outputs8 peak-and-holdIgnition outputs8ConfigurationMTune; check the release appropriate to the ECU and hardware revision

ProcessorThe manufacturer product page lists an ARM Cortex-M3 main processor running at 120 MHz, with three further processors handling the triggers, injectors and EGT (manufacturer specification). The specific microcontroller part number is not published.

Identification and installation

The V1 wiring archive includes separate REV5+ and REV9+ documents. Identify the actual hardware revision before choosing a connector diagram or wideband sensor; do not assume a RACE replacement has identical wiring.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

Complete 48-way connector 1 positions from the manufacturer’s model-specific column. A dash in the source is shown as not assigned. Consult the drawing for orientation and the remaining connectors. Exact wiring and connector reference.PositionManufacturer functionNotesA1GPO 5A2IGN 1A3IGN 2A4GPO 8/TACHO660ohm pullupB1GPO 6B2IGN 3B3IGN 4B4GPO 1C1GPO 7C2IGN 5C3IGN 6C4GPO 2D1WBO2 Heater-D2IGN 7D3IGN 8D4GPO 3E1CAN HE2CAN LE3GND ShieldE4GPO 4F1CLTF2IATF3WBO2 VREFF4WBO2 VSG1+5V sensor supply(peak 0.5A, max 150mA)G2TPS/AING3WBO2 IPG4WBO2 RCALH1Sensor GNDH2Trigger GNDH3TRIGGERH4HOMEJ1AIN 1 (Temperature)J2AIN 2 (Temperature)J3AIN 3 (0-5V)J4AIN 4 (0-5V)K1INJ 1K2INJ 2K3DIN/VR 1K4DIN/VR 2L1INJ 8L2INJ 7L3INJ 6L4Engine GNDM1INJ 3M2INJ 4M3INJ 5M4+12V ECU power supplySelected GEN1 connector 1 positions common in the manufacturer’s comparison. Use the exact V1 revision diagram and its orientation for the rest. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.PositionFunctionA2Ignition 1A3Ignition 2A4GPO 8 / tachoB2Ignition 3B3Ignition 4B4GPO 1C2Ignition 5C3Ignition 6C4GPO 2D1Wideband heater negativeD4GPO 3E1CAN highE2CAN lowE3Shield groundF1Coolant temperatureF2Air temperatureF3Wideband VREFF4Wideband VS

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

All positions of the GEN1 connectors, including this unit's, are listed as a structured pin index in MaxxECU GEN1 connector pinout.

Software and further documents

MaxxECU V1: product informationModel wiring and pinout referenceMTune, quick-start guides and revision-specific wiring downloadsMaxxECU family overview

Sources reviewed 17 November 2026.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 1: MaxxECU V1

MaxxECU V1 — Discontinued first-generation MaxxECU, superseded by RACE according to the manufacturer. MaxxECU product information.

MaxxECU V1
MaxxECU V1, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

V1 has eight peak-and-hold injector outputs and eight ignition outputs, supporting up to eight sequential cylinders or twelve with wasted spark. The manufacturer lists eight EGT inputs, built-in wideband and a 400 kPa MAP sensor. Rev 6 raised injector output capability; Rev 7 added logging and digital-input changes; Rev 9 added LSU 4.9 support. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum8
Injector outputs8 peak-and-hold
Ignition outputs8
ConfigurationMTune; check the release appropriate to the ECU and hardware revision

Identification and installation

The V1 wiring archive includes separate REV5+ and REV9+ documents. Identify the actual hardware revision before choosing a connector diagram or wideband sensor; do not assume a RACE replacement has identical wiring.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

Selected GEN1 connector 1 positions common in the manufacturer’s comparison. Use the exact V1 revision diagram and its orientation for the rest. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.

PositionFunction
A2Ignition 1
A3Ignition 2
A4GPO 8 / tacho
B2Ignition 3
B3Ignition 4
B4GPO 1
C2Ignition 5
C3Ignition 6
C4GPO 2
D1Wideband heater negative
D4GPO 3
E1CAN high
E2CAN low
E3Shield ground
F1Coolant temperature
F2Air temperature
F3Wideband VREF
F4Wideband VS

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

Software and further documents

Sources reviewed 17 November 2026.

Revision 3: MaxxECU V1

MaxxECU V1 — Discontinued first-generation MaxxECU, superseded by RACE according to the manufacturer. MaxxECU product information.

MaxxECU V1
MaxxECU V1, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

V1 has eight peak-and-hold injector outputs and eight ignition outputs, supporting up to eight sequential cylinders or twelve with wasted spark. The manufacturer lists eight EGT inputs, built-in wideband and a 400 kPa MAP sensor. Rev 6 raised injector output capability; Rev 7 added logging and digital-input changes; Rev 9 added LSU 4.9 support. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum8
Injector outputs8 peak-and-hold
Ignition outputs8
ConfigurationMTune; check the release appropriate to the ECU and hardware revision

Processor

The manufacturer product page lists an ARM Cortex-M3 main processor running at 120 MHz, with three further processors handling the triggers, injectors and EGT (manufacturer specification). The specific microcontroller part number is not published.

Identification and installation

The V1 wiring archive includes separate REV5+ and REV9+ documents. Identify the actual hardware revision before choosing a connector diagram or wideband sensor; do not assume a RACE replacement has identical wiring.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

Complete 48-way connector 1 positions from the manufacturer’s model-specific column. A dash in the source is shown as not assigned. Consult the drawing for orientation and the remaining connectors. Exact wiring and connector reference.

PositionManufacturer functionNotes
A1GPO 5
A2IGN 1
A3IGN 2
A4GPO 8/TACHO660ohm pullup
B1GPO 6
B2IGN 3
B3IGN 4
B4GPO 1
C1GPO 7
C2IGN 5
C3IGN 6
C4GPO 2
D1WBO2 Heater-
D2IGN 7
D3IGN 8
D4GPO 3
E1CAN H
E2CAN L
E3GND Shield
E4GPO 4
F1CLT
F2IAT
F3WBO2 VREF
F4WBO2 VS
G1+5V sensor supply(peak 0.5A, max 150mA)
G2TPS/AIN
G3WBO2 IP
G4WBO2 RCAL
H1Sensor GND
H2Trigger GND
H3TRIGGER
H4HOME
J1AIN 1 (Temperature)
J2AIN 2 (Temperature)
J3AIN 3 (0-5V)
J4AIN 4 (0-5V)
K1INJ 1
K2INJ 2
K3DIN/VR 1
K4DIN/VR 2
L1INJ 8
L2INJ 7
L3INJ 6
L4Engine GND
M1INJ 3
M2INJ 4
M3INJ 5
M4+12V ECU power supply

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

All positions of the GEN1 connectors, including this unit's, are listed as a structured pin index in MaxxECU GEN1 connector pinout.

Software and further documents

Sources reviewed 17 November 2026.