MaxxECU V1 — Discontinued first-generation MaxxECU, superseded by RACE according to the manufacturer. MaxxECU product information.

Model identification and capabilities
V1 has eight peak-and-hold injector outputs and eight ignition outputs, supporting up to eight sequential cylinders or twelve with wasted spark. The manufacturer lists eight EGT inputs, built-in wideband and a 400 kPa MAP sensor. Rev 6 raised injector output capability; Rev 7 added logging and digital-input changes; Rev 9 added LSU 4.9 support. Manufacturer specification; MaxxECU model comparison.
| Sequential cylinders, maximum | 8 |
|---|---|
| Injector outputs | 8 peak-and-hold |
| Ignition outputs | 8 |
| Configuration | MTune; check the release appropriate to the ECU and hardware revision |
Identification and installation
The V1 wiring archive includes separate REV5+ and REV9+ documents. Identify the actual hardware revision before choosing a connector diagram or wideband sensor; do not assume a RACE replacement has identical wiring.
Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.
Connector and pinout
Selected GEN1 connector 1 positions common in the manufacturer’s comparison. Use the exact V1 revision diagram and its orientation for the rest. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.
| Position | Function |
|---|---|
| A2 | Ignition 1 |
| A3 | Ignition 2 |
| A4 | GPO 8 / tacho |
| B2 | Ignition 3 |
| B3 | Ignition 4 |
| B4 | GPO 1 |
| C2 | Ignition 5 |
| C3 | Ignition 6 |
| C4 | GPO 2 |
| D1 | Wideband heater negative |
| D4 | GPO 3 |
| E1 | CAN high |
| E2 | CAN low |
| E3 | Shield ground |
| F1 | Coolant temperature |
| F2 | Air temperature |
| F3 | Wideband VREF |
| F4 | Wideband VS |
Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.
Software and further documents
- MaxxECU V1: product information
- Model wiring and pinout reference
- MTune, quick-start guides and revision-specific wiring downloads
- MaxxECU family overview