MaxxECU SPORT — Six-cylinder sequential wire-in ECU with peak-and-hold injection and electronic-throttle outputs. MaxxECU product information.

Model identification and capabilities
SPORT has six peak-and-hold injector outputs, six ignition outputs, seven general ground outputs and two motor outputs. Inputs include two trigger inputs, two extra temperatures, six extra 0–5 V inputs, two digital inputs, an internal 400 kPa MAP sensor and a wideband controller for LSU 4.2/4.9. Its product page describes Bluetooth for MDash and USB for MTune. Manufacturer specification; MaxxECU model comparison.
| Sequential cylinders, maximum | 6 |
|---|---|
| Injector outputs | 6 peak-and-hold |
| Ignition outputs | 6 |
| Configuration | MTune; check the release appropriate to the ECU and hardware revision |
Identification and installation
SPORT has different assignments from STREET and V1 on several positions of connector 1. Verify both connector columns and ECU revision; 5 V ignition signals require a suitable igniter or smart coil.
Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.
Connector and pinout
Selected 48-way connector 1 positions; these are shared in the manufacturer’s comparison. Consult the SPORT column for all positions and the physical view. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.
| Position | Function |
|---|---|
| A2 | Ignition 1 |
| A3 | Ignition 2 |
| A4 | GPO 8 / tacho |
| B2 | Ignition 3 |
| B3 | Ignition 4 |
| B4 | GPO 1 |
| C2 | Ignition 5 |
| C3 | Ignition 6 |
| C4 | GPO 2 |
| D1 | Wideband heater negative |
| D4 | GPO 3 |
| E1 | CAN high |
| E2 | CAN low |
| E3 | Shield ground |
| F1 | Coolant temperature |
| F2 | Air temperature |
| F3 | Wideband VREF |
| F4 | Wideband VS |
Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.