Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Reference hub
Subject
Engine ECU
Parent
MaxxECU standalone engine management
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None

Changes from revision 1 to revision 2

Removed text is struck through; added text is highlighted.

MaxxECU MINI — Compact entry ECU with four injector and four ignition outputs; up to four fully sequential cylinders or eight in wasted spark. MaxxECU product information.

MaxxECU MINI, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

A 400 kPa absolute MAP sensor is built in. The MINI has one VR/Hall trigger, two extra Hall/digital inputs and two extra 0–5 V analogue inputs in addition to its named temperature and throttle inputs. The manufacturer specifies four auxiliary outputs and 8 MB of internal logging, up to 1000 Hz. CAN and USB are available. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum4Injector outputs4 high-impedanceIgnition outputs4ConfigurationMTune; check the release appropriate to the ECU and hardware revision

Identification and installation

It does not include an internal wideband controller: use the documented external analogue or CAN solution. Injector outputs are intended for high-impedance injectors; observe the manufacturer’s instructions for low-impedance injectors and external current limiting.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

MINI connector 1, REV10+; see the linked manufacturer drawing for the connector face and its cavity positions. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.

PositionManufacturer functionNotesA1TRIGGERA2TRIGGER GNDA3Not assigned in sourceA4Not assigned in sourceB1DIN 1 (Hall onLY)B2DIN 2 (Hall only)B3SENSOR GNDB4SENSOR GNDC1CLTC2IATC3AIN 3 (0-5V)C4AIN 4 (0-5V)D1GPO 8/TACHO660ohm pullupD2TPSD3GND ShieldD4SENSOR GNDE1GPO 3E2+5V sensor supply(peak 0.5A, max 150mA)E3CAN LRead important note below if you encounter issues with CAN communications!E4CAN HRead important note below if you encounter issues with CAN communications!F1IGN 1F2IGN 2F3IGN 3F4IGN 4G1GPO 2G2GPO 1G3INJ 1G4ENGINE GNDH1INJ 2H2INJ 3H3INJ 4H4+12V (ECU power supply)PositionFunctionA1TriggerA2Trigger groundB1Digital input 1B2Digital input 2B3, B4Sensor groundC1Coolant temperatureC2Air temperatureC3, C4Analogue 3, 4 respectivelyD1GPO 8 / tachometerD2Throttle positionD3ShieldD4Sensor groundE1GPO 3E25 V sensor supplyE3CAN lowE4CAN highF1–F4Ignition 1–4 respectivelyG1GPO 2G2GPO 1G3Injector 1G4Engine groundH1–H3Injector 2–4 respectivelyH412 V ECU supply

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

MaxxECU reports that approximately the first 100 MINI harnesses delivered in 2019 had CAN H and CAN L swapped in harness labelling; ECU positions remain E4 CAN H and E3 CAN L. Verify the actual loom against the manufacturer’s harness notice.

Software and further documents

MaxxECU MINI: product informationModel wiring and pinout referenceMTune, quick-start guides and revision-specific wiring downloadsMaxxECU family overview

Sources reviewed 17 November 2026.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 1: MaxxECU MINI

MaxxECU MINI — Compact entry ECU with four injector and four ignition outputs; up to four fully sequential cylinders or eight in wasted spark. MaxxECU product information.

MaxxECU MINI
MaxxECU MINI, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

A 400 kPa absolute MAP sensor is built in. The MINI has one VR/Hall trigger, two extra Hall/digital inputs and two extra 0–5 V analogue inputs in addition to its named temperature and throttle inputs. The manufacturer specifies four auxiliary outputs and 8 MB of internal logging, up to 1000 Hz. CAN and USB are available. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum4
Injector outputs4 high-impedance
Ignition outputs4
ConfigurationMTune; check the release appropriate to the ECU and hardware revision

Identification and installation

It does not include an internal wideband controller: use the documented external analogue or CAN solution. Injector outputs are intended for high-impedance injectors; observe the manufacturer’s instructions for low-impedance injectors and external current limiting.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

MINI connector 1, REV10+; see the linked manufacturer drawing for the connector face and its cavity positions. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.

PositionFunction
A1Trigger
A2Trigger ground
B1Digital input 1
B2Digital input 2
B3, B4Sensor ground
C1Coolant temperature
C2Air temperature
C3, C4Analogue 3, 4 respectively
D1GPO 8 / tachometer
D2Throttle position
D3Shield
D4Sensor ground
E1GPO 3
E25 V sensor supply
E3CAN low
E4CAN high
F1–F4Ignition 1–4 respectively
G1GPO 2
G2GPO 1
G3Injector 1
G4Engine ground
H1–H3Injector 2–4 respectively
H412 V ECU supply

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

Software and further documents

Sources reviewed 17 November 2026.

Revision 2: MaxxECU MINI

MaxxECU MINI — Compact entry ECU with four injector and four ignition outputs; up to four fully sequential cylinders or eight in wasted spark. MaxxECU product information.

MaxxECU MINI
MaxxECU MINI, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

A 400 kPa absolute MAP sensor is built in. The MINI has one VR/Hall trigger, two extra Hall/digital inputs and two extra 0–5 V analogue inputs in addition to its named temperature and throttle inputs. The manufacturer specifies four auxiliary outputs and 8 MB of internal logging, up to 1000 Hz. CAN and USB are available. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum4
Injector outputs4 high-impedance
Ignition outputs4
ConfigurationMTune; check the release appropriate to the ECU and hardware revision

Identification and installation

It does not include an internal wideband controller: use the documented external analogue or CAN solution. Injector outputs are intended for high-impedance injectors; observe the manufacturer’s instructions for low-impedance injectors and external current limiting.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

MINI connector 1, REV10+; see the linked manufacturer drawing for the connector face and its cavity positions. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.

PositionManufacturer functionNotes
A1TRIGGER
A2TRIGGER GND
A3Not assigned in source
A4Not assigned in source
B1DIN 1 (Hall onLY)
B2DIN 2 (Hall only)
B3SENSOR GND
B4SENSOR GND
C1CLT
C2IAT
C3AIN 3 (0-5V)
C4AIN 4 (0-5V)
D1GPO 8/TACHO660ohm pullup
D2TPS
D3GND Shield
D4SENSOR GND
E1GPO 3
E2+5V sensor supply(peak 0.5A, max 150mA)
E3CAN LRead important note below if you encounter issues with CAN communications!
E4CAN HRead important note below if you encounter issues with CAN communications!
F1IGN 1
F2IGN 2
F3IGN 3
F4IGN 4
G1GPO 2
G2GPO 1
G3INJ 1
G4ENGINE GND
H1INJ 2
H2INJ 3
H3INJ 4
H4+12V (ECU power supply)

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

MaxxECU reports that approximately the first 100 MINI harnesses delivered in 2019 had CAN H and CAN L swapped in harness labelling; ECU positions remain E4 CAN H and E3 CAN L. Verify the actual loom against the manufacturer’s harness notice.

Software and further documents

Sources reviewed 17 November 2026.