Removed text is struck through; added text is highlighted.
Manufacturer product photograph: Cosworth. Permission to republish confirmed by the user.
The Antares 4 is a Cosworth Antares family ECU and vehicle controller. Cosworth describes it as a lower-cost entry in its Antares range while retaining data-logging and powertrain-control functions. Cosworth product information.
Manufacturer product specificationCosworth's Antares 4 product page describes optimisation for 4-cylinder GDI or 8-cylinder port injection; it lists 3 CAN ports, 4 GB logging, two onboard lambda inputs, two knock inputs and three H-bridge pairs. Maximum counts include alternative functions, so they are not necessarily simultaneously available. Confirm hardware and enabled strategy against the current build.A separate family comparison leaflet gives different cylinder/driver figures from the product page; these should not be reconciled without revision-specific confirmation. Use the exact build sheet and software from Cosworth for the installation.
Identification and control
Confirm the exact ordered configuration and obtain the matching connector and calibration documents from Cosworth. Antares family feature headlines do not establish that every feature is enabled on this particular unit. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
Software and support
Cosworth's Pectel application notes cover model-specific strategies; confirm toolchain and access level with the supplier. See the Cosworth Pectel and Antares family for related controllers.
Connector schedules in Cosworth’s Antares 4 sheetThe tables list all 66 numbered positions for each of four connectors from Cosworth’s Antares 4 product sheet, cover version 0.3. Signal names and connector part numbers follow that sheet; “not labelled in source” denotes an empty signal cell and must not be read as a confirmed unused pin. Where the sheet shows two pins for one signal, both are listed individually. Consult the source for the paired-pin notation, wiring, current limits, optional functions, grounds and orientation.Document identification discrepancy: the cover and ordering table identify Antares 4 and product 01E-501154, but the final page identifies document 29E-501156-P, revision 1.0; 01E-501156 is identified elsewhere by Cosworth as Antares 6. The cover and final page also show different version numbers. Confirm the document and pin assignments for the exact unit directly with Cosworth before wiring.C1 — AS218-35PN-943B; mating AS618-35SNPinSignal in source1INJLS2/PWM42INJHS2/PWM33IGN4/PWM464INJLS1/PWM25INJHS1/PWM16BATT-7IGN4/PWM468IGN3/PWM459IGN2/PWM4410INJHS4/PWM711BATT-12BATT-13Serial2_TX_CTRL14IGN3/PWM4515IGN2/PWM4416IGN1/PWM4317INJLS4/PWM818BATT+19BATT-20BATT-21Serial2_RX_CTRL22SerialDBG_RX_LOG23IGN1/PWM4324Serial1_TX_LOG25INJLS11/PWM1926BATT+27BATT+28BATT-29BATT+30SerialDBG_TX_LOG31DOUT2/PWM5232Serial1_RX_LOG33ETHTRX-134INJLS12/PWM2035BATT+36BATT+37BATT-38BATT+39DOUT1/PWM5140DOUT4/PWM5441ETHTRX+142ETHTX-143INJHS3/PWM544BATT+45HBB2/PWM3646BATT-47CANH_CTRL-LOG48DOUT3/PWM5349HBA1/PWM3350ETHTX+151INJLS3/PWM652HBB2/PWM3653HBA2/PWM3554BATT-55CANL_CTRL-LOG56HBB1/PWM3457HBA1/PWM3358INJLS9/PWM1759INJLS10/PWM1860HBA2/PWM3561BATT-62INJLS14/PWM2263HBB1/PWM3464INJLS15/PWM2365INJLS16/PWM2466INJLS13/PWM21C2 — AS218-35PA-943B; mating AS618-35SAPinSignal in source1ECATTX+2ECATRX-3ETH1000+44EXTPSU115EXTPSU126ECATTX-7ECATRX+8ETH1000-49ETH1000-310EXTPSU1311EXTPSU1412CANL_LOG13CANH_LOG14N/C15ETH1000+316ETH1000+217EXTPSU418EXTPSU219DOUT8/PWM5820DOUT6/PWM5621DOUT7/PWM5722N/C23ETH1000-224ETH1000+125EXTPSU326EXTPSU127AIN228AIN129AIN430DOUT5/PWM5531Not labelled in source32ETH1000-133DIN1/AIN34TCNEG235LamTrim236LamTrim137AIN538AIN639AIN340Not labelled in source41DIN2/AIN42LAMVS143TCPOS244TCPOS145DIN6/AIN46N / C47KNOCK148N / C49LAMIP150KNOCK251TCNEG152DIN7/AIN53DIN4/AIN54Not labelled in source55DIN5/AIN56DIN3/AIN57LAMVS258DIN8/AIN59Not labelled in source60PROT-GND261N / C62CRANK163LAMIP264PROT-GND165PROT-GND266CAMC3 — AS218-35SN-943B; mating AS618-35PNPinSignal in source1Not labelled in source2EXTPSU193ETH2_TX- /FM14AIN HS1/CPM15Not labelled in source6EXTPSU217ETH2_TX+ /FP18ETH2_RX- /FM29ETH2_RX+ /FP210AIN HS3/CPM311N/C12Not labelled in source13N/C14N/C15CANL_CTRL16CANH_CTRL17AIN HS4/CPM418AIN HS2/CPM219N/C20Not labelled in source21PT1000 1 / AIN22AIN1823AIN1324AIN1425N/C26Not labelled in source27Not labelled in source28Not labelled in source29Not labelled in source30N/C31AIN1732AIN1133AIN1234N/C35N/C36Not labelled in source37Not labelled in source38Not labelled in source39AIN1640DIN HS2/AIN41AIN942AIN1043N/C44PROT-GND345AIN846AIN1947AIN1548DIN HS1/AIN49EXTPSU1850EXTPSU1651PROT-GND352PROT-GND453AIN754N/C55N/C56ScopeOut257ScopeOut158PROT-GND459EXTPSU560EXTPSU661EXTPSU762EXTPSU1563EXTPSU1764EXTPSU865EXTPSU966EXTPSU10C4 — AS218-35SA-943B; mating AS618-35PAPinSignal in source1N/C2IGN5/PWM473IGN6/PWM484N/C5N/C6IGN5/PWM477IGN6/PWM488IGN7/PWM499IGN8/PWM5010N/C11BATT-12BATT-13BATT-14IGN7/PWM4915IGN8/PWM5016N/C17N/C18Not labelled in source19BATT-20LIN121Not labelled in source22Not labelled in source23N/C24Not labelled in source25N/C26BATT-27BATT-28LIN229Not labelled in source30Not labelled in source31N/C32N/C33EXTPSU2034INJLS19 / PWM2735BATT+36N/C37Not labelled in source38Not labelled in source39N/C40N/C41N/C42EXTPSU2243INJLS20 / PWM2844BATT+45BATT+46HBB3/PWM3847N/C48Not labelled in source49PROT-GND550PROT-GND551N/C52BATT+53HBB3/PWM3854HBA3/PWM3755Not labelled in source56PROT-GND657PROT-GND658N/C59INJLS17 / PWM2560HBA3/PWM3761Not labelled in source62N/C63N/C64INJLS18 / PWM2665N/C66N/C
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 1: Cosworth Antares 4
The Antares 4 is a Cosworth Antares family ECU and vehicle controller. Cosworth describes it as a lower-cost entry in its Antares range while retaining data-logging and powertrain-control functions. Cosworth product information.
Identification and control
Confirm the exact ordered configuration and obtain the matching connector and calibration documents from Cosworth. Antares family feature headlines do not establish that every feature is enabled on this particular unit. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
Revision 4: Cosworth Antares 4Manufacturer product photograph: Cosworth. Permission to republish confirmed by the user.
The Antares 4 is a Cosworth Antares family ECU and vehicle controller. Cosworth describes it as a lower-cost entry in its Antares range while retaining data-logging and powertrain-control functions. Cosworth product information.
Manufacturer product specification
Cosworth's Antares 4 product page describes optimisation for 4-cylinder GDI or 8-cylinder port injection; it lists 3 CAN ports, 4 GB logging, two onboard lambda inputs, two knock inputs and three H-bridge pairs. Maximum counts include alternative functions, so they are not necessarily simultaneously available. Confirm hardware and enabled strategy against the current build.
A separate family comparison leaflet gives different cylinder/driver figures from the product page; these should not be reconciled without revision-specific confirmation. Use the exact build sheet and software from Cosworth for the installation.
Identification and control
Confirm the exact ordered configuration and obtain the matching connector and calibration documents from Cosworth. Antares family feature headlines do not establish that every feature is enabled on this particular unit. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
The tables list all 66 numbered positions for each of four connectors from Cosworth’s Antares 4 product sheet, cover version 0.3. Signal names and connector part numbers follow that sheet; “not labelled in source” denotes an empty signal cell and must not be read as a confirmed unused pin. Where the sheet shows two pins for one signal, both are listed individually. Consult the source for the paired-pin notation, wiring, current limits, optional functions, grounds and orientation.
Document identification discrepancy: the cover and ordering table identify Antares 4 and product 01E-501154, but the final page identifies document 29E-501156-P, revision 1.0; 01E-501156 is identified elsewhere by Cosworth as Antares 6. The cover and final page also show different version numbers. Confirm the document and pin assignments for the exact unit directly with Cosworth before wiring.