Cosworth Pectel MQ12 ECU. Image: Cosworth, reproduced with permission.
Cosworth launched the Pectel MQ12 in 2008 to replace its T10s. Its sheet describes 20 configurable injector/PWM drivers, 12 IGBT and 16 logic-level ignition outputs, with fully sequential fuelling for up to 12 cylinders. Cosworth product information.
Identification and control
The MQ12 sheet includes connector pinouts and ratings, 22,000 rpm capability, two lambda inputs, eight knock inputs and software-configurable shared functions. Hardware options and strategy licensing must be checked. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
Complete connector pin assignmentsThe assignments reproduce the Cosworth MQ12 product sheet 29E-071624-1E. Connector letters are case-sensitive: for example “a” is not “A”. Confirm the connector view, power supply, individual driver ratings and build-specific configuration in the original document before wiring.Connector 1 — AS216-26PA-943BPinSignal in sourceWBATTNEGXBATTNEGYBATTNEGcBATTNEGFBATTPOSVBATTPOSBFuel/PWM1AFuel/PWM2TFuel/PWM3bFuel/PWM4PFuel/PWM5ZFuel/PWM6NFuel/PWM7aFuel/PWM8SFuel/PWM9RFuel/PWM10CH-Bridge 1AUH-Bridge 1BDH-Bridge 2AEH-Bridge 2BGSpark1HSpark2JSpark3KSpark4LSpark5MSpark6Connector 2 — ASDD214-64PN-970MPinSignal in source35V/12V_5205V/12V_6185V/12V_7165V/12V_851Cam1CAN_HA2CAN_LA26CAN_HB44CAN_LB43CAN_HC / ALT_TX42CAN_LC / ALT_RX52Crank136Crank235DIN123DIN234DIN322DIN433DIN511DIN632DIN721DIN831DIN941DIN1050DIN118DIN1249DIN137DIN1430DIN156DIN1627DOUT145DOUT258DOUT357DOUT440DOUT556DOUT639DOUT755DOUT862DOUT963DOUT1061DOUT1164DOUT1238DOUT1354DOUT1437DOUT1553DOUT169Ethernet_RX+13Ethernet_TX-12Ethernet_TX+4ExtGnd619ExtGnd717ExtGnd815ExtGnd914ExtGnd1048Knock147Knock229Knock328Knock460Knock559Knock646Knock75Knock824RS232_RX25RS232_TX10Ethernet_RX-Connector 3 — ASDD214-64PA-970MPinSignal in source45V/12V_1175V/12V_2195V/12V_3215V/12V_452AIN151AIN213AIN312AIN411AIN510AIN69AIN78AIN87AIN96AIN1015AIN1114AIN1236AIN1335AIN1434AIN1533AIN1632AIN1731AIN1850AIN1949AIN2030AIN2148AIN2247AIN2329AIN2428AIN2546AIN2645AIN2727AIN2843AIN2940AIN3039AIN3138AIN3237AIN3342AIN3441AIN3526AIN3644AIN375ExtGnd116ExtGnd218ExtGnd320ExtGnd422ExtGnd523LambdaIP254LambdaVS153LambdaVS2615V_9625V_1025V_1135V_12255V_1315V_14595V_15605V_1663TC1NEG58TC1POS57TC2NEG64TC2POS55TC3NEG56TC3POS24LambdaIP1Connector 4 — AS216-26PN-943BPinSignal in sourceVBATTNEGWBATTNEGXBATTNEGYBATTNEGbBATTNEGcBATTNEGGBATTPOSHBATTPOSLFuel/PWM11MFuel/PWM12ZFuel/PWM13aFuel/PWM14SFuel/PWM15UFuel/PWM16TFuel/PWM17RFuel/PWM18PFuel/PWM19NFuel/PWM20JH-Bridge 3AKH-Bridge 3BFSpark7ESpark8DSpark9CSpark10BSpark11ASpark12
Software and support
Cosworth's Pectel application notes cover model-specific strategies; confirm toolchain and access level with the supplier. See the Cosworth Pectel and Antares family for related controllers.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 1: Cosworth MQ12
Cosworth launched the Pectel MQ12 in 2008 to replace its T10s. Its sheet describes 20 configurable injector/PWM drivers, 12 IGBT and 16 logic-level ignition outputs, with fully sequential fuelling for up to 12 cylinders. Cosworth product information.
Identification and control
The MQ12 sheet includes connector pinouts and ratings, 22,000 rpm capability, two lambda inputs, eight knock inputs and software-configurable shared functions. Hardware options and strategy licensing must be checked. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
Revision 3: Cosworth MQ12Cosworth Pectel MQ12 ECU. Image: Cosworth, reproduced with permission.
Cosworth launched the Pectel MQ12 in 2008 to replace its T10s. Its sheet describes 20 configurable injector/PWM drivers, 12 IGBT and 16 logic-level ignition outputs, with fully sequential fuelling for up to 12 cylinders. Cosworth product information.
Identification and control
The MQ12 sheet includes connector pinouts and ratings, 22,000 rpm capability, two lambda inputs, eight knock inputs and software-configurable shared functions. Hardware options and strategy licensing must be checked. Document the exact part number, serial, software build, calibration, championship configuration and any security or software option before assessing compatibility.
Connectors and wiring
Review the model-specific Cosworth document and request the current build sheet where necessary. Connector and driver assignments may be model-, build- and configuration-dependent. Sensor supplies, peak driver currents, earths and high-voltage injector circuits must be matched to the official document.
Complete connector pin assignments
The assignments reproduce the Cosworth MQ12 product sheet 29E-071624-1E. Connector letters are case-sensitive: for example “a” is not “A”. Confirm the connector view, power supply, individual driver ratings and build-specific configuration in the original document before wiring.