Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Tuning
Parent
Bosch Motronic 7
Applies to
Bosch ME7.1, Bosch ME7.5
Tool groups
None
Manufacturers
Audi, Volkswagen

Scope: an adaptive integral limit

In the Bosch Audi R4-5V turbo 132 kW ME7.1 function description, LDRPID uses proportional, integral and derivative components, an operating-state-dependent integral limit, and a post-regulator linearisation. The description below is a reference for that documented function, not proof that all ME7 files use identical control or memory layouts.

The long NefMoto PID discussion contains an explanation of KFLDIMX as a feed-forward or pilot value followed by a clarification: in the example, it limits the integral contribution and is not a simple switch that replaces the regulator at zero error. Bosch describes an adaptively adjusted integral-limit strategy. Do not equate the table cell, the current limit, the current integral output and final N75 duty.

Compare the right signals

Example signal or mapRole in the cited Bosch description
B_ldr and ldeControl-active condition and pressure deviation. In this Bosch function, when boost regulation is inactive, lde is set to zero; zero therefore needs the state flag before it can be read as good tracking.
KFLDIMX, ldimxr_w, ldimx_wReference map and internal values involved in the integral maximum-limit path. Other corrections and operating conditions can affect the current limit.
ldimxa / ldimxa_0–ldimxa_4Adaptive correction values. Bosch describes five adaptation regions for the cited function; the linked logger alias list labels five example channels. Check whether they are present and how they are represented in the actual software.
ldimxak_wThe current corrected integral-limit value in the Bosch table. Do not assume this signal is simply the raw learned correction or a final wastegate duty.
lditv_w, ldptv, ldrdtvExample I, P and D regulator contributions. They may change differently during a transient and after it settles.
ldtvr_w, ldtvm, KFLDRLExample regulator output before linearisation, modulated final command, and the post-regulator transformation. Verify the control path and signal definitions in the fitted ECU.

Channel labels are corroborated by the ME7Logger alias reference; availability, scaling, signedness and addresses remain software-specific. Requested and actual pressure must also be compared at the same physical location and pressure reference.

Why a final duty is not an integral-limit value

For illustration only, suppose the relevant linearisation at one RPM maps a regulator output of 70% to a final command of 85%. Seeing 85% final duty does not prove the I term or its limit was 85%. P, D, adaptation and other path elements may contribute before the output transformation. Even when the I term dominates, the appropriate pre-transformation value must be understood from the actual table and operating state; an inverse is not necessarily unique outside a suitable monotonic region. This is not a tuning value.

The same NefMoto thread discusses this pre- versus post-linearisation distinction. Another participant's simplified description calls a map input a boost error; Bosch lists KFLDIMX inputs as engine speed and a relative requested-pressure signal in this function, so verify the axis rather than accepting the forum label.

Read the adaptation history

Bosch describes conditions and delays for moving the reference and storing adaptation, including whether regulation is active and whether the controller is at a limit. The learned value can therefore differ between otherwise similar runs. A Golf 1.8T case reports a boost drop changing after an axis edit; contributors requested the individual regulator and adaptation channels. The forum account is not an independently reproduced diagnosis.

Retain the software, sensor scaling, faults, learned values, temperature, gear and time history before a reset or map change. Compare repeatable steady operation and transients. If a pressure sensor or representation clips, the controller may not see the true error; an adaptation reset cannot establish that the sensor, actuator or calibration is sound. See ME7 5120 pressure scaling and wastegate hardware. Avoid forcing oscillations or copying gains from an unrelated file.

Related: comparing spool and steady state · boost and load log review · torque, load and boost control.