Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Reference hub
Subject
Engine ECU
Parent
Simos
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None

The first Simos

Volkswagen Self-Study Programme 165, December 1994, introduces Simos as the engine-management system that follows Digifant. Load comes from the air-mass meter and from engine speed. From those two, the control unit calculates injection duration and ignition timing, then applies the corrections. The functions named in that programme are cylinder-selective knock control, lambda control, idle control on the air side through the throttle control unit and by ignition timing, and charcoal-canister control. The programme says the functions are adaptive.

The crankshaft sensor in that system is a Hall sensor on a toothed wheel. The VR6 of the same period used an inductive sender for the same job. If the speed signal is lost, the fuel pump is switched off: the engine does not start, or it stalls. The programme is a teaching text. The workshop literature is the procedure for the car in front of you.

Simos 3.3 on the APF

Self-Study Programme 222 is the first place this wiki has a numbered Simos tied to an engine code. The electronically mapped cooling system appears first on the 1.6-litre inline-four, code APF, 74 kW. The programme says further engines were in preparation, and it names Simos 3.3 as the engine management that contains the cooling functions.

The maps it lists inside that controller are a coolant-temperature setpoint from engine speed and load, a second setpoint from road speed and intake-air temperature, a pre-control duty factor from the setpoint and engine speed, and two maps for the temperature difference that brings in the radiator fan at its first and second speed. The controller drives the heater in the thermostat and the two fan outputs. It reads the radiator return temperature and the potentiometer at the heater controls. The rest of the engine sensors already on the controller supply the other inputs. A Simos 3.3 label on a different engine is not, by this programme, the APF installation.

Other Simos 3 suffixes

An OBDSTAR coverage note lists Simos 3.3A, 3.4A and 3PA through 3PG as Siemens memory layouts for Audi, SEAT, Škoda and Volkswagen, each described with an external flash and an EEPROM. That list is what the tool claims to address. It is not a vehicle fitment list, and those suffixes are not Simos 18 or Simos 19. The number after Simos is read from the controller, then matched to the software of that car.

Later Volkswagen direct-injection petrol engines were also run by Bosch MED controllers. SSP 253 is the Bosch Motronic MED 7 account of petrol direct injection. A direct-injection Volkswagen is not automatically a Simos.

Sources

  • Volkswagen / Audi Self-Study Programme 165, Simos engine management, December 1994. Successor to Digifant; load, knock, lambda, idle and canister functions. SSP 165 PDF. Catalogue note: SSP 165 record. Accessed 2026-11-13.
  • Volkswagen Self-Study Programme 222, Electronically Mapped Cooling System. APF 1.6, 74 kW, and the Simos 3.3 maps for that cooling system. SSP 222 PDF. Accessed 2026-11-13.
  • OBDSTAR DC706 coverage note, June 2024 software. Simos 3.3A, 3.4A and 3PA–3PG named as Siemens layouts for Audi, SEAT, Škoda and Volkswagen. Coverage note. Accessed 2026-11-13.