What the SIMAF is for
The Siemens VDO integrated mass-airflow sensor, SIMAF, measures the mass of fresh air entering the engine. On a petrol engine that mass, with the other sensors, sets the fuel quantity. On a diesel it sets the exhaust-gas recirculation rate. The same signal is used for diagnosis. The accuracy and the speed of the reading are what keep the emissions correction honest: a slow or drifting meter lets the mixture or the EGR rate wander before the control unit can see it.
Hot-film bridge
The sensor is a hot-film anemometer. Two metal-film resistors sit in the sensor’s own flow channel and form a bridge. RT tracks the incoming air so that the flow element RS is held a fixed temperature above it. The current needed to hold that offset is the mass-flow signal. The electronics read it as the voltage across the fixed bridge resistor R2, then turn it into an analogue voltage, a frequency, or a ratiometric analogue voltage for the control unit.
There are no moving parts. Calibration is stored in programmable ROM, with up to nine points, in a DSP-based programmable ASIC. Sensor tolerance is ±2 %. The meter can be a plug-in element or built into the tube. A flow conditioner and an intake-air temperature sensor are optional. The connector can be arranged to suit the housing. Switch-on time is 200 ms. The signal reaches 63 % of a change in under 30 ms. The smallest connector is three pins.
Pulsation and reverse flow
Engines with four cylinders or fewer often set up large oscillations in the intake. An ordinary thermal meter then counts some of the air twice, or misses the reverse part of the wave, and the error depends on the length of the manifold and on whether a resonance flap has just moved. The SIMAF’s own flow channel compensates that pulsation error. The compensation does not depend on the resonant frequency, on temperature, on air pressure, or on intake-manifold length switching. Reverse-flow compensation is held to ±5 % for a modulation under 200 %.
A Bosch HFM 5 also detects return flow, with a different element and a fixed analogue curve for each part number. The SIMAF curve is programmed into the sensor, so two sensors of the same family can carry different output shapes, including frequency as well as voltage.