The sensor
The 20.3855 is a hot-film air-mass meter. Heat lost from the film depends on the speed of the air around it, and the meter turns that mass flow into a normalised DC voltage for an engine-control unit or for another system. It is fitted in the intake, between the air filter and the throttle. Nominal supply is 12 V, and it runs from 7.5 to 16 V. Mass is at most 200 g. The terminals are marked 1 to 5. The housing also carries a flow arrow, the 12 V marking, and the month and year of manufacture.
Current, between 7.5 and 16 V, is at most 500 mA inside the working flow range, and at most 1000 mA for the first 200 ms after switch-on. During that same 200 ms the output may rise as high as 6.5 V. Output resistance is 100 Ω. Working ambient temperature is −45 to +125 °C. Flow temperature is −40 to +110 °C. Ambient pressure is 84 to 106.7 kPa.
Flow range and the output curve
At the nominal supply the conversion range is 8 to 550 kg/h. From 7.5 to 9 V the range is only 8 to 140 kg/h, so a weak supply does not merely shift the voltage: it shortens the flow the meter can report. With no flow the output is 0.02 V. The nominal curve, output voltage against mass flow, is:
| kg/h | V |
|---|---|
| 0 | 0.02 |
| 4.93 | 0.22 |
| 7.90 | 0.50 |
| 11.95 | 0.78 |
| 41.31 | 1.80 |
| 61.54 | 2.20 |
| 106.69 | 2.80 |
| 183.49 | 3.40 |
| 402.05 | 4.30 |
| 465.83 | 4.50 |
| 572.73 | 4.80 |
At 23 ± 5 °C and 14.0 ± 0.2 V, two check points bound a new meter and a meter after 3000 hours:
| kg/h | New, V | After 3000 h, V |
|---|---|---|
| 41.31 | 1.728 to 1.872 | 1.692 to 1.908 |
| 402.05 | 4.128 to 4.472 | 4.042 to 4.558 |
Other check flows may be used if they are at least 200 kg/h apart and are taken from the curve above, with intermediate points by spline interpolation. Temperature error on the voltage, for a new meter and after 3000 hours, is ±6 % and ±8 % at −40 °C, ±4 % and ±6 % at −20 °C, ±4 % and ±6 % at 70 °C, and ±6 % and ±8 % at 110 °C. Between those temperatures the limit is a straight interpolation.
From 15 to 320 kg/h the output reaches 63 % of the final value within 20 ms and 95 % within 80 ms. Pressure drop at 550 kg/h is at most 1.6 kPa in normal climatic conditions. Reverse-flow pulsation from 25 to 200 Hz, with modulation up to 200 %, is compensated to within ±9 %.
Temperature resistor
At 25 ± 0.2 °C the thermistor is 2014 ± 74.5 Ω. It may be measured at another temperature and brought back to the 25 °C value by spline interpolation. Nominal resistance, with the allowed band:
| °C | Minimum, Ω | Nominal, Ω | Maximum, Ω |
|---|---|---|---|
| −40 | 41255 | 44373 | 47492 |
| −20 | 14260 | 15141 | 16022 |
| 0 | 5497 | 5774 | 6050 |
| 20 | 2353 | 2448 | 2544 |
| 25 | 1940 | 2014 | 2089 |
| 40 | 1114 | 1150 | 1186 |
| 60 | 568.9 | 583.1 | 597.4 |
| 80 | 310 | 315.8 | 321.6 |
| 100 | 180.4 | 182.8 | 185.1 |
| 120 | 108.9 | 110.3 | 111.8 |
What the meter must survive
The body, apart from the sensing element itself, is sealed to IP55S. It is a non-repairable part. Ninety per cent of meters are expected to reach 3000 hours, taken as 150 000 km over 10 years. A failure is a broken housing or an output outside the check-point band above.
It remains within that band after vibration for 2 hours on each of three axes, 50 m/s² from 10 to 100 Hz and 100 m/s² from 100 to 500 Hz. It also remains within band after three half-sine shocks of 1000 m/s² and 11 ms on each axis, and after 330 half-sine shocks of 250 m/s² and 6 ms on each axis. Temperature cycling is ten transfers between −40 and +115 °C, half an hour at each extreme, with no more than 3 minutes between chambers. Humidity is 95 ± 3 % at 40 ± 2 °C for 96 hours. Fuel, oil and automotive wash chemicals are part of the same endurance set. Each terminal, including the joint, holds a 50 ± 3 N pull along its axis.
The electronics survive 18 V for 2 hours at no more than 65 °C, and 25 V for 5 minutes in normal conditions. Reverse supply, or a short from the signal terminal to the common terminal or to the +12 V terminal, is survived for 1 minute. If the wiring is unscreened, any run that lies parallel to a high-voltage pulse line such as ignition or injection is kept to 0.3 m or less. The thermistor’s own interference immunity is provided by the control unit, not by the sensor.
Fitting
The duct between the intake mouth and the meter keeps a constant diameter. A bend upstream changes the conversion curve, so the bend angle is part of the calibration and is not a free choice. The meter may be rolled to any angle about the duct axis. The sensing element itself is vertical, 90° either way, within 5°. The flow arrow on the housing is the direction of flow. Any later change to the intake geometry has to be agreed as a new calibration. The meter is not opened and is not repaired.
A signal converter exists specifically to turn this sensor’s voltage into an HFM 5 curve. The 20.3855’s peak current is the reason that converter must not take its 12 V feed from the control-unit side of an HFM 5 plug.