What the HFM 2 measures
The Bosch HFM 2 is a hot-film air-mass meter. It measures the mass of air, or of another gas, passing in a unit of time. The reading does not have to be corrected afterwards for density or temperature, because the cooling of the film already depends on the mass flow. There are no moving parts. The film is less sensitive to dirt than a hot-wire meter, so the control unit does not run a burn-off cycle to clean it.
The meter is used to give an engine-control unit the air mass it needs for a controlled mixture. Five housings are listed. Four characteristic curves cover 10 to 350, 10 to 480, 12 to 640 and 20 to 1080 kg/h. Accuracy on those curves is ±4 % of the measured value. Supply is 14 V. Current is at most 0.25 A with no flow and at most 0.8 A at the nominal flow. After a step from 10 kg/h to 0.7 of nominal flow, the signal reaches 63 % of its final value in 20 ms or less. Sustained temperature is −30 to +110 °C, and a short excursion may reach −40 to +125 °C. Pressure drop at the nominal air mass is under 15 hPa. Vibration acceleration may reach 150 m/s².
| Part number | Curve | Flow, kg/h | Installation length, mm |
|---|---|---|---|
| 0 280 217 102 | 1 | 10 to 350 | 130 |
| 0 280 217 120 | 2 | 10 to 480 | 130 |
| 0 280 217 519 | 3 | 12 to 640 | 130 |
| 0 280 217 801 | 4 | 20 to 1080 | 130 |
| 0 280 217 107 | 96 |
The short housing, 0 280 217 107, is listed with the family. Its flow curve is not given on the same row as the four 130 mm meters, so match that sensor by the number on the housing.
How the film is kept hot
The sensing element is a ceramic substrate with thick-film resistors printed onto it: an air-temperature resistor RT, a heater RH, a sensor resistor RS, and a trimmer R1. The heater holds the platinum film RS a constant temperature above the incoming air. RS and RH are in close thermal contact. Incoming-air temperature acts on RT. R1 is in series with RT and trims out the bridge’s temperature sensitivity over the operating range.
R1, R2 and RT form one arm of the bridge. An auxiliary resistor R3 and the sensor resistor RS form the other. The voltage difference across the bridge diagonal is the measurement signal. A second thick-film hybrid carries the evaluation circuit. Both hybrids sit in the plastic housing of the plug-in sensor. The film is exposed to the air in the measuring venturi.
The output voltage rises with mass flow. The four curves are not interchangeable: the same voltage means a different mass flow on a different part number. A control unit calibrated for one curve will meter the wrong fuel on another.
Connector
| Pin | Function |
|---|---|
| 1 | Ground |
| 2 | Signal UA− |
| 3 | Supply UV |
| 4 | Signal UA+ |
0 280 217 102, 0 280 217 107 and 0 280 217 801 use plug S1. The housing for that plug is 1 284 485 118, with receptacle 1 284 477 121 and protective cap 1 280 703 023. Each plug needs one housing, four receptacles and one cap. 0 280 217 120 and 0 280 217 519 use plug S2. That plug housing is 1 928 403 112. Contact pins are 1 987 280 103 for 0.5 to 1.0 mm² and 1 987 280 105 for 1.5 to 2.5 mm², with individual gaskets 1 987 280 106 and 1 987 280 107 for the same two wire sizes. Each of those plugs needs one housing, four pins and four gaskets. The contacts are crimped with the original AMP tool.
Installation
Water and other liquids must not collect in the measuring venturi, so the venturi is inclined at least 5° from the horizontal. The intake air has to be free of dust, which means an air filter is part of the installation. Dust on the film changes the heat transfer and therefore the mass reading.
The later micromechanical meter, the HFM 5, uses a different element, a five-pin connector and return-flow detection. The two families do not share a pinout or a curve.