Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Tuning Tools
Parent
Section level
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
Bosch, Siemens

Changes from revision 1 to revision 1

Removed text is struck through; added text is highlighted.

What it does

The maf2maf converter takes the voltage from a Siemens 20.3855 air-mass meter and produces the voltage an engine-control unit expects from a Bosch HFM 5. It is the way a failed HFM 5 is replaced by a 20.3855. Conversion covers 8 to 570 kg/h, which is the working range of the 20.3855. Four curves can be stored. Jumpers select which one is used, and the choice is read when the ignition comes on.

Supply is 12 to 14 V. Ambient temperature is −40 to +80 °C. Input voltage is 0 to 5 V and output voltage is 1 to 4.98 V. Conversion error is 2.1 % at 8 kg/h, 0.5 % at 100 kg/h and 0.01 % at 280 kg/h. Current is 50 to 150 mA with Bluetooth in use. The 20.3855 itself can draw up to 1 A at switch-on. An HFM 5 draws about 100 mA. The control-unit pin that fed the HFM 5 is not rated for the Siemens current, so the converter’s +12 V comes from a relay that closes in the first ignition position. It does not come from the air-mass plug that the control unit is feeding. The battery is disconnected before the wiring is cut, so a short cannot feed the control unit.

Ground is taken from the control-unit side of the air-mass plug. Using that ground, rather than a separate body screw, keeps supply noise off the output. HFM 5 plugs are not all pinned the same way, so the pin numbers on the car are confirmed before the three converter wires are landed.

Signals toward the control unit

OUT goes to the signal pin of the control-unit plug. GND goes to the ground pin of that same plug. TEMP goes to the temperature pin of that plug, so the control unit still sees an air-temperature sensor.

Choosing a stored curve

Jumpers are moved only with the ignition off. Changing them with the supply on can destroy the converter.

J1Curve index No jumper1 Jumper on contacts 1–22 Jumper on contacts 3–43 Jumpers on 1–2 and on 3–44

Any other combination on J1 is invalid. A jumper on contact 9 or contact 10 blocks Bluetooth.

Programming

Curves are written from Windows software or from an Android app, into index 1, 2, 3 or 4. Writing an index replaces whatever was already stored there. The converter does not advertise a device name: the computer or the phone shows a Bluetooth address. On Windows that connection appears as a new COM port, and the software is pointed at that port. On Android the app searches for the device itself. The default access code is 1234.

A curve is shaped by the coefficients a, t, n and k, and the graph updates as they change. A stored example curve can be copied in as the starting point. Drawing the same curve twice and editing only one of them shows the difference. After a write, the ignition is cycled if that index is the one the jumpers have selected, so the converter loads it. If the written index is not the selected one, the ignition does not have to be cycled.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 1: maf2maf converter

What it does

The maf2maf converter takes the voltage from a Siemens 20.3855 air-mass meter and produces the voltage an engine-control unit expects from a Bosch HFM 5. It is the way a failed HFM 5 is replaced by a 20.3855. Conversion covers 8 to 570 kg/h, which is the working range of the 20.3855. Four curves can be stored. Jumpers select which one is used, and the choice is read when the ignition comes on.

Supply is 12 to 14 V. Ambient temperature is −40 to +80 °C. Input voltage is 0 to 5 V and output voltage is 1 to 4.98 V. Conversion error is 2.1 % at 8 kg/h, 0.5 % at 100 kg/h and 0.01 % at 280 kg/h. Current is 50 to 150 mA with Bluetooth in use. The 20.3855 itself can draw up to 1 A at switch-on. An HFM 5 draws about 100 mA. The control-unit pin that fed the HFM 5 is not rated for the Siemens current, so the converter’s +12 V comes from a relay that closes in the first ignition position. It does not come from the air-mass plug that the control unit is feeding. The battery is disconnected before the wiring is cut, so a short cannot feed the control unit.

Ground is taken from the control-unit side of the air-mass plug. Using that ground, rather than a separate body screw, keeps supply noise off the output. HFM 5 plugs are not all pinned the same way, so the pin numbers on the car are confirmed before the three converter wires are landed.

Signals toward the control unit

  • OUT goes to the signal pin of the control-unit plug.
  • GND goes to the ground pin of that same plug.
  • TEMP goes to the temperature pin of that plug, so the control unit still sees an air-temperature sensor.

Choosing a stored curve

Jumpers are moved only with the ignition off. Changing them with the supply on can destroy the converter.

J1Curve index
No jumper1
Jumper on contacts 1–22
Jumper on contacts 3–43
Jumpers on 1–2 and on 3–44

Any other combination on J1 is invalid. A jumper on contact 9 or contact 10 blocks Bluetooth.

Programming

Curves are written from Windows software or from an Android app, into index 1, 2, 3 or 4. Writing an index replaces whatever was already stored there. The converter does not advertise a device name: the computer or the phone shows a Bluetooth address. On Windows that connection appears as a new COM port, and the software is pointed at that port. On Android the app searches for the device itself. The default access code is 1234.

A curve is shaped by the coefficients a, t, n and k, and the graph updates as they change. A stored example curve can be copied in as the starting point. Drawing the same curve twice and editing only one of them shows the difference. After a write, the ignition is cycled if that index is the one the jumpers have selected, so the converter loads it. If the written index is not the selected one, the ignition does not have to be cycled.

Revision 1: maf2maf converter

What it does

The maf2maf converter takes the voltage from a Siemens 20.3855 air-mass meter and produces the voltage an engine-control unit expects from a Bosch HFM 5. It is the way a failed HFM 5 is replaced by a 20.3855. Conversion covers 8 to 570 kg/h, which is the working range of the 20.3855. Four curves can be stored. Jumpers select which one is used, and the choice is read when the ignition comes on.

Supply is 12 to 14 V. Ambient temperature is −40 to +80 °C. Input voltage is 0 to 5 V and output voltage is 1 to 4.98 V. Conversion error is 2.1 % at 8 kg/h, 0.5 % at 100 kg/h and 0.01 % at 280 kg/h. Current is 50 to 150 mA with Bluetooth in use. The 20.3855 itself can draw up to 1 A at switch-on. An HFM 5 draws about 100 mA. The control-unit pin that fed the HFM 5 is not rated for the Siemens current, so the converter’s +12 V comes from a relay that closes in the first ignition position. It does not come from the air-mass plug that the control unit is feeding. The battery is disconnected before the wiring is cut, so a short cannot feed the control unit.

Ground is taken from the control-unit side of the air-mass plug. Using that ground, rather than a separate body screw, keeps supply noise off the output. HFM 5 plugs are not all pinned the same way, so the pin numbers on the car are confirmed before the three converter wires are landed.

Signals toward the control unit

  • OUT goes to the signal pin of the control-unit plug.
  • GND goes to the ground pin of that same plug.
  • TEMP goes to the temperature pin of that plug, so the control unit still sees an air-temperature sensor.

Choosing a stored curve

Jumpers are moved only with the ignition off. Changing them with the supply on can destroy the converter.

J1Curve index
No jumper1
Jumper on contacts 1–22
Jumper on contacts 3–43
Jumpers on 1–2 and on 3–44

Any other combination on J1 is invalid. A jumper on contact 9 or contact 10 blocks Bluetooth.

Programming

Curves are written from Windows software or from an Android app, into index 1, 2, 3 or 4. Writing an index replaces whatever was already stored there. The converter does not advertise a device name: the computer or the phone shows a Bluetooth address. On Windows that connection appears as a new COM port, and the software is pointed at that port. On Android the app searches for the device itself. The default access code is 1234.

A curve is shaped by the coefficients a, t, n and k, and the graph updates as they change. A stored example curve can be copied in as the starting point. Drawing the same curve twice and editing only one of them shows the difference. After a write, the ignition is cycled if that index is the one the jumpers have selected, so the converter loads it. If the written index is not the selected one, the ignition does not have to be cycled.