Link G4+ Monsoon is a programmable G4+ wire-in engine-management ECU. Earlier single A loom model; guide lists four analogue voltage inputs and two temperature inputs. Its injection channels are not available as spare switching outputs in the guide. Link G4+ Monsoon quick-start guide.
Model identification and I/O
ItemDocumented detailsECU familyG4+Outputs4 injection and 4 ignition drivesProgrammingPCLink version matched to ECU generation and firmwareConnector and loomSee the exact-model guide, including connector keys, wire-side orientation and optional functions
The manufacturer guidance and wiring identify the hardware; driver counts do not establish injector electrical compatibility or imply all multiplexed pins can be used at the same time.
Model-specific pinout and installation
The G4+ Monsoon quick-start guide provides the connector diagrams and installer I/O table. Refer to that version for numbered cavities, wire colours, supply, grounds, driver and sensor connection notes. Loom wire-side and ECU header views are identified on the diagram; do not transfer a pin number from another generation.
Software and further sources
Download software, firmware and full installation help from Link's download centre; identify the ECU generation and installed firmware before choosing a PCLink package. The legacy software list separates G5, G4X and G4+ compatibility. See also Link standalone ECUs.
34-position A connector
Link’s G4+ Monsoon quick-start guide, page 3, shows these assignments and colours when looking into the wire side of the loom connector, or into the ECU header. Numbering follows its four-row G4+ diagram. Confirm the actual loom and generation before wiring; this is not the later MonsoonX schedule.
PinFunctionWire colourA1Inj 4Brown/orangeA2Inj 3Brown/redA3Inj 2BrownA4Inj 1Brown/blackA5+14 VRedA6DI 4Red/whiteA7Shield/groundGreenA8Trigger 1BlackA9Trigger 2RedA10Ignition 4Blue/orangeA11Ignition 3Blue/redA12Ignition 2Blue/brownA13Ignition 1BlueA14Analog volt 4White/blackA15Temperature 1YellowA16Temperature 2Yellow/brownA17Analog volt 1Yellow/blueA18Auxiliary 4OrangeA19Auxiliary 3Orange/redA20Auxiliary 2Orange/brownA21Auxiliary 1Orange/blackA22Analog volt 2White/brownA23DI 3Grey/redA24Ground outGreenA25GroundBlackA26Auxiliary 6Orange/purpleA27Auxiliary 5Orange/blueA28CAN highOrange/greenA29CAN lowOrange/yellowA30DI 1Grey/blackA31DI 2Grey/brownA32+5 VRed/blueA33Analog volt 3Yellow/blackA34GroundBlack
The header is redrawn with every pin in Link G4+ Monsoon connector pinout.
Link G4+ family illustration
Link G4+ Atom shown only as a family illustration; the Monsoon model and its connectors differ. Manufacturer image: Link G4+ catalogue, reproduced with permission.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 4: Link G4+ Monsoon
Link G4+ Monsoon is a programmable G4+ wire-in engine-management ECU. Earlier single A loom model; guide lists four analogue voltage inputs and two temperature inputs. Its injection channels are not available as spare switching outputs in the guide. Link G4+ Monsoon quick-start guide.
Model identification and I/O
Item
Documented details
ECU family
G4+
Outputs
4 injection and 4 ignition drives
Programming
PCLink version matched to ECU generation and firmware
Connector and loom
See the exact-model guide, including connector keys, wire-side orientation and optional functions
The manufacturer guidance and wiring identify the hardware; driver counts do not establish injector electrical compatibility or imply all multiplexed pins can be used at the same time.
Model-specific pinout and installation
The G4+ Monsoon quick-start guide provides the connector diagrams and installer I/O table. Refer to that version for numbered cavities, wire colours, supply, grounds, driver and sensor connection notes. Loom wire-side and ECU header views are identified on the diagram; do not transfer a pin number from another generation.
Software and further sources
Download software, firmware and full installation help from Link's download centre; identify the ECU generation and installed firmware before choosing a PCLink package. The legacy software list separates G5, G4X and G4+ compatibility. See also Link standalone ECUs.
34-position A connector
Link’s G4+ Monsoon quick-start guide, page 3, shows these assignments and colours when looking into the wire side of the loom connector, or into the ECU header. Numbering follows its four-row G4+ diagram. Confirm the actual loom and generation before wiring; this is not the later MonsoonX schedule.
Link G4+ Atom shown only as a family illustration; the Monsoon model and its connectors differ. Manufacturer image: Link G4+ catalogue, reproduced with permission.Revision 4: Link G4+ Monsoon
Link G4+ Monsoon is a programmable G4+ wire-in engine-management ECU. Earlier single A loom model; guide lists four analogue voltage inputs and two temperature inputs. Its injection channels are not available as spare switching outputs in the guide. Link G4+ Monsoon quick-start guide.
Model identification and I/O
Item
Documented details
ECU family
G4+
Outputs
4 injection and 4 ignition drives
Programming
PCLink version matched to ECU generation and firmware
Connector and loom
See the exact-model guide, including connector keys, wire-side orientation and optional functions
The manufacturer guidance and wiring identify the hardware; driver counts do not establish injector electrical compatibility or imply all multiplexed pins can be used at the same time.
Model-specific pinout and installation
The G4+ Monsoon quick-start guide provides the connector diagrams and installer I/O table. Refer to that version for numbered cavities, wire colours, supply, grounds, driver and sensor connection notes. Loom wire-side and ECU header views are identified on the diagram; do not transfer a pin number from another generation.
Software and further sources
Download software, firmware and full installation help from Link's download centre; identify the ECU generation and installed firmware before choosing a PCLink package. The legacy software list separates G5, G4X and G4+ compatibility. See also Link standalone ECUs.
34-position A connector
Link’s G4+ Monsoon quick-start guide, page 3, shows these assignments and colours when looking into the wire side of the loom connector, or into the ECU header. Numbering follows its four-row G4+ diagram. Confirm the actual loom and generation before wiring; this is not the later MonsoonX schedule.
Link G4+ Atom shown only as a family illustration; the Monsoon model and its connectors differ. Manufacturer image: Link G4+ catalogue, reproduced with permission.