Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Engine ECU
Parent
Link G4+ Atom
Applies to
Link G4+ Atom, Link G4+ Atom II
Tool groups
None
Manufacturers
Link

Connector pinout

The Link G4+ Atom and G4+ Atom II use a single 34-way A loom header arranged in four rows of 9, 8, 8 and 9 cavities, with the shorter middle rows set half a cavity in from the ends. Link's G4+ Atom quick start guide (manufacturer documentation) draws the header viewed into the wire side of the loom connector, or into the ECU header, and gives the function and loom colour of 29 cavities; five cavities are blank in the drawing. Link's guide prints no cavity numbers. AiM's connection guide for Link G4+ ECUs (tool vendor documentation) shows the same drawing for the G4+ Atom II, prints the row-end numbers 1, 9, 26 and 34, and gives CAN H and CAN L as pins 28 and 29. This fixes the reading-order numbering 1–34 used here, which also matches the numbering in Link's 2010 G4 manual for the same header.

The header carries four injector drives (1–4), four ignition outputs (10–13), two trigger inputs (8 and 9), four auxiliary outputs (18–21), two digital inputs (30 and 31), two temperature inputs (15 and 16), three analogue voltage inputs (17, 22 and 33) and CAN H and CAN L (28 and 29). Power and reference cavities are +14 V (5), +5 V (32), ground (25 and 34), ground out (24) and shield/ground (7). The pin index gives each cavity's loom colour.

The layout applies to the G4+ Atom and G4+ Atom II. The original G4 Atom uses a different 26-position header (see Link G4 Atom original connector pinout), and AtomX must be checked separately. Confirm the actual unit and loom before wiring.

Link G4+ Atom 34-way A loom header with cavity numbers and functions
34-way A loom header, viewed into the wire side of the loom connector. Diagram redrawn by Tuning Wiki from Link's G4+ Atom quick start guide.

Sources

  • G4+ Atom quick start guide. Link Engine Management, manufacturer quick start guide; A loom drawing on page 3. Accessed 19 November 2026.
  • Link G4+ Series ECUs. AiM InfoTech connection guide, release 1.01; G4+ Atom II 34-pin connector with row-end numbers and CAN pins on page 3. Accessed 19 November 2026.
  • G4 wiring and installation manual. Link Electrosystems, manufacturer installation manual, 2010; numbered 34-pin header drawing on page 18. Accessed 19 November 2026.

Connector pinout

Applicability

Link G4+ Atom and G4+ Atom II (single 34-way A loom). Functions and loom colours from Link's G4+ Atom quick start guide (page 3), which draws the header viewed into the wire side of the loom connector (or into the ECU header) without cavity numbers. AiM's Link G4+ series connection guide (release 1.01, page 3) shows the same drawing for the G4+ Atom II, prints row-end numbers 1, 9, 26 and 34 and gives CAN H and CAN L as pins 28 and 29, which fixes the reading-order numbering 1-34 (rows of 9, 8, 8 and 9) used here; it matches the numbering in Link's 2010 G4 manual for the same header. Five cavities (6, 14, 23, 26 and 27) are blank in the drawing and have no function listed. Does not apply to the original G4 Atom or AtomX.

View orientation is stated beside each photograph. Unknown functions remain in the pin index.

A loom header (34-way)

Redrawn connector face
View: Viewed into the wire side of the loom connector (or into the ECU header), as drawn by the manufacturer
A loom header (34-way) — Redrawn connector face. Viewed into the wire side of the loom connector (or into the ECU header), as drawn by the manufacturer

Select a pin in a photograph or the index to highlight it.

A loom header (34-way) — complete pin index
PinFunction / cavityConfidence / sourceNotes
Inj 4
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Brown/orange.
Inj 3
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Brown/red.
Inj 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Brown.
Inj 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Brown/black.
+14 V
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Red.
Unknown function
Cavity: Unknown
Unknown Blank in the manufacturer drawing; no function shown.
Shield / ground
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Green.
Trigger 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Black.
Trigger 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Red.
Ignition 4
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Blue/orange.
Ignition 3
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Blue/red.
Ignition 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Blue/brown.
Ignition 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Blue.
Unknown function
Cavity: Unknown
Unknown Blank in the manufacturer drawing; no function shown.
Temperature 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Yellow.
Temperature 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Yellow/brown.
Analogue volt 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Yellow/blue.
Aux 4
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Orange.
Aux 3
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Orange/red.
Aux 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Orange/brown.
Aux 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Orange/black.
Analogue volt 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour White/brown.
Unknown function
Cavity: Unknown
Unknown Blank in the manufacturer drawing; no function shown.
Ground out
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Green.
Ground
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Black.
Unknown function
Cavity: Unknown
Unknown Blank in the manufacturer drawing; no function shown.
Unknown function
Cavity: Unknown
Unknown Blank in the manufacturer drawing; no function shown.
CAN H
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Orange/green.
CAN L
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Orange/yellow.
Digital input 1
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Grey/black.
Digital input 2
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Grey/brown.
+5 V
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Red/blue.
Analogue volt 3
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Yellow/black.
Ground
Cavity: Populated
Confirmed

Link G4+ Atom quick start guide, p. 3

Loom colour Black.