Emerald K6 is a 32-bit programmable engine-management ECU introduced in early 2010. Emerald specifies six injection and six ignition drivers, allowing sequential control for up to six cylinders. Emerald K6 specification.
Inputs, outputs and interfaces
- Three configurable inductive or digital speed-trigger inputs for crank, cam or distributor.
- Internal barometric pressure sensor; engine load by TPS and/or 0–5 V MAP signal.
- Six injector drivers and six configurable ignition drivers. The manufacturer's page describes active-high use with external amplifiers or active-low direct coil control.
- RS232 communication and CAN 2.0B up to 1 Mbit/s; up to four road-speed inputs.
- Adaptive lambda uses a suitable external wideband controller with 0–5 V output; K6 also accepts a narrowband signal.
Emerald's specification gives a 6.5–18 V operating supply, 110 × 190 × 44 mm case, IP65 enclosure and IP68 connectors. Features and pins must be checked against the actual hardware and configuration.
Wiring and identification
Obtain the K6 quick-start, configuration guide and K3/K6 manual from Emerald's software and manuals page. Emerald also supplies vehicle-specific adapters; those adapters do not make every factory harness interchangeable. The manufacturer notes that individual units can have bespoke software, so quote the serial number when in doubt.
See Emerald standalone ECUs and the separate K6+ reference.
COMMS nine-way connector
Race Technology’s K3/K6 CAN integration instructions identify the left-hand COMMS connector and the following RS232 and CAN assignments. Check orientation and firmware on the actual ECU; its CAN protocol may require configuration.
| Pin | Function |
|---|---|
| 1 | CAN high |
| 2 | CAN low |
| 3 | Not used |
| 4 | Not used |
| 5 | Signal earth |
| 6 | Not used |
| 7 | RS232 receive |
| 8 | RS232 transmit |
| 9 | RS232 clear to send |
Selected original K6 main-connector assignments
The Emerald K6 configuration guide, 1 March 2012, identifies the following positions. This is a partial table: other 36-way cavities and hardware revisions must be checked against the ECU’s own specification.
| ECU pin | Documented example |
|---|---|
| 4 | Ignition driver 3 in an appropriate six-cylinder configuration, otherwise potentially main relay control |
| 5 | Ignition driver 2 in the illustrated wasted-spark configuration |
| 7 | Narrowband oxygen sensor signal |
| 18 | Narrowband oxygen sensor signal ground |
| 35 | Common example for a 0–5 V wideband controller signal; other configurable auxiliary inputs are possible |
| 36 | AuxOut36, example narrowband sensor heater control |
Structured connector pins
The documented main-connector positions above and the COMMS connector are given as structured pin indexes in Emerald K6 original ECU connector pinout. Emerald's K6 part-loom wiring details also give a complete 36-way table for a drive-by-wire loom, structured in Emerald K6 and K6+ 36-way connector pinout. Emerald's specification describes the K6 as a 32-bit ECU but does not name its microcontroller.