Link G4X XtremeX is a programmable G4X wire-in engine-management ECU. Two loom connectors, electronic throttle, two knock inputs and 11 analogue voltage inputs. The manufacturer's guide identifies digital inputs 9/10 as shared with CAN 2. Link G4X XtremeX quick-start guide.
Model identification and I/O
| Item | Documented details |
|---|---|
| ECU family | G4X |
| Outputs | 8 injection and 8 ignition drives |
| Programming | PCLink version matched to ECU generation and firmware |
| Connector and loom | See the exact-model guide, including connector keys, wire-side orientation and optional functions |
The manufacturer guidance and wiring identify the hardware; driver counts do not establish injector electrical compatibility or imply all multiplexed pins can be used at the same time.
Model-specific pinout and installation
The G4X XtremeX quick-start guide provides the connector diagrams and installer I/O table. Refer to that version for numbered cavities, wire colours, supply, grounds, driver and sensor connection notes. Loom wire-side and ECU header views are identified on the diagram; do not transfer a pin number from another generation.
Engine applications
As a universal wire-in ECU the XtremeX is not tied to an engine. With eight injection and eight ignition drives it is offered for up to eight cylinders or four rotors with sequential injection and direct spark, and with electronic throttle control; retailers do not list direct-injection support (dealer listings).
Connector pinout
Both 34-way loom connectors are drawn, with every cavity indexed, in the Link G4X XtremeX connector pinout.
Complete loom connector tables
The following positions are transcribed from the Link XTREMEX quick-start guide. They are viewed into the ECU header or the wire side of the loom, as illustrated in the source. Unlabelled positions are shown as such, rather than assumed unused. Colours apply to the documented loom; outputs and shared functions depend on ECU hardware version and configuration. Refer to the original for keying, current limits and full installation diagrams.
A/B loom connector A — 34-way
| Pin | Function in guide | Loom colour |
|---|---|---|
| 1 | Injector 4 | Brown/Orange |
| 2 | Injector 3 | Brown/Red |
| 3 | Injector 2 | Brown |
| 4 | Injector 1 | Brown/Black |
| 5 | +14 V | Red |
| 6 | +8 V | Red/White |
| 7 | Shield/Ground | Green |
| 8 | Trigger 1 | Black |
| 9 | Trigger 2 | Red |
| 10 | Ignition 4 | Blue/Orange |
| 11 | Ignition 3 | Blue/Red |
| 12 | Ignition 2 | Blue/Brown |
| 13 | Ignition 1 | Blue |
| 14 | Analogue voltage 4 | White/Black |
| 15 | Temperature 1 | Yellow |
| 16 | Temperature 2 | Yellow/Brown |
| 17 | Analogue voltage 1 | Yellow/Blue |
| 18 | Auxiliary 4 | Orange |
| 19 | Auxiliary 3 | Orange/Red |
| 20 | Auxiliary 2 | Orange/Brown |
| 21 | Auxiliary 1 | Orange/Black |
| 22 | Analogue voltage 2 | White/Brown |
| 23 | Digital input 3 | Grey/Red |
| 24 | Ground out | Green |
| 25 | Ground | Black |
| 26 | Auxiliary 8 | Orange/Purple |
| 27 | Auxiliary 7 | Orange/Blue |
| 28 | Auxiliary 6 | Orange/Green |
| 29 | Auxiliary 5 | Orange/Yellow |
| 30 | Digital input 1 | Grey/Black |
| 31 | Digital input 2 | Grey/Brown |
| 32 | +5 V | Red/Blue |
| 33 | Analogue voltage 3 | Yellow/Black |
| 34 | Ground | Black |
A/B loom connector B — 34-way
| Pin | Function in guide | Loom colour |
|---|---|---|
| 1 | Injector 8 | Brown/Purple |
| 2 | Injector 7 | Brown/Blue |
| 3 | Injector 6 | Brown/Green |
| 4 | Injector 5 | Brown/Yellow |
| 5 | V Ethrottle | Red |
| 6 | Temperature 3 | Yellow/Red |
| 7 | Temperature 4 | Yellow/Orange |
| 8 | Knock 2 | White |
| 9 | Knock 1 | White |
| 10 | Ignition 8 | Blue/Purple |
| 11 | Ignition 7 | Blue/Black |
| 12 | Ignition 6 | Blue/Green |
| 13 | Ignition 5 | Blue/Yellow |
| 14 | Not labelled in guide | — |
| 15 | Analogue voltage 6 | White/Red |
| 16 | Analogue voltage 7 | White/Orange |
| 17 | Shield/Ground | Green |
| 18 | Auxiliary 9 | Purple |
| 19 | Digital input 6 | Grey/Green |
| 20 | Digital input 5 | Grey/Yellow |
| 21 | Digital input 4 | Grey/Orange |
| 22 | Ground out | Green |
| 23 | Analogue voltage 8 | White/Yellow |
| 24 | Analogue voltage 9 | White/Green |
| 25 | Ground | Black |
| 26 | Auxiliary 10 | Purple/White |
| 27 | Digital input 10 / CAN 2 high | Grey/Purple |
| 28 | Digital input 9 / CAN 2 low | Grey/White |
| 29 | Digital input 8 | Grey |
| 30 | Digital input 7 | Grey/Blue |
| 31 | Analogue voltage 10 | White/Blue |
| 32 | Analogue voltage 11 | White |
| 33 | Analogue voltage 5 | Yellow/Green |
| 34 | Ground | Black |
Software and further sources
Download software, firmware and full installation help from Link's download centre; identify the ECU generation and installed firmware before choosing a PCLink package. The legacy software list separates G5, G4X and G4+ compatibility. See also Link standalone ECUs.
Sources
- Link Engine Management: G4X XtremeX quick-start guide, manufacturer documentation. Accessed 19 November 2026.
- Automotive Superstore: Link G4X XtremeX wire-in ECU 109-4000 and Torqen: Link ECU G4X XtremeX, dealer listings. Seen in search summary, 19 November 2026.