Connector
The Motorsport Electronics GEN2 wire-in range (ME221, ME360 and ME442) uses a single sealed 90-way FCI main connector with a common pinout. According to the manufacturer, the three models share the pin assignments but not every channel: the ME221 GEN2 is aimed at four-cylinder engines, the ME360 GEN2 at six-cylinder and complex four-cylinder engines (for example with drive-by-wire), and the ME442 GEN2 is the fully featured eight-cylinder unit with every channel populated. Header crimps are listed as part number 211CC2S1160P.
Pin assignments
All 90 pins are listed with the manufacturer's function and notes, and each pin records which models provide it. Channels common to all three include coils 1 to 4, injectors 1 to 4, low-side outputs 1 to 6, the LSU 4.9 wideband interface (pins 15, 16, 19, 20, 49 and 50), CAN 1 (high pin 21, low pin 51), USB, RS232 serial, crank VR (80/81), cam A VR (22/23), knock 1, stepper outputs, tachometer and analogue/temperature inputs. Switched 12 V supply is on pins 14 and 64, power grounds on 10, 61, 89 and 90, and sensor grounds on 52 and 84; the manufacturer directs all sensors to return to pin 52. The ME360 adds coils 5 and 6, injectors 5 and 6, the drive-by-wire H-bridge (65/66), cam B VR (82/83), EGT 1, extra digital inputs and relay drivers. Coils 7 and 8, injectors 7 and 8, knock 2 and several analogue inputs are ME442-only. Pin 85 is not used.
The manufacturer documentation does not show the face of the 90-way header, so the drawing is a numbered pin index rather than a connector view. Assignments are manufacturer documentation (graded confirmed). The table does not apply to GEN1 wire-in units (ME221/ME100 GEN1 28-way, ME442 REV C/D) or to vehicle-specific plug-in boards. Confirm the unit's generation, model and firmware configuration before wiring.
Diagram redrawn by Tuning Wiki from the Motorsport Electronics GEN2 wire-in pinout. See the ME221, ME360 and ME442 hubs.
Sources
- Motorsport Electronics, ME442/ME360/ME221 GEN2 Wire-In Pinout, online manual, with ME221 and ME360 availability columns. Manufacturer documentation. Accessed 19 November 2026.
- Motorsport Electronics Limited, ME221/360/442 GEN2 90-Way Quick Install Guide (PDF), introduction, connector, grounds and Appendix A (ME442 GEN2 has every channel). Manufacturer documentation. Accessed 19 November 2026.
Connector pinout
Motorsport Electronics ME221, ME360 and ME442 GEN2 wire-in ECUs (common 90-way FCI header). Functions and per-model availability from the manufacturer GEN2 wire-in pinout; ME442 GEN2 has every channel. Not applicable to GEN1 wire-in units (ME221 GEN1 28-way, ME442 REV C/D) or to vehicle-specific plug-in boards. Drawing is a numerical pin index; the header face layout is not published.
View orientation is stated beside each photograph. Unknown functions remain in the pin index.
GEN2 main connector (90-way FCI)
View: Pin index; connector face layout not shown in source
Select a pin in a photograph or the index to highlight it.
| Pin | Function / cavity | Confidence / source | Notes |
|---|---|---|---|
| COIL 4 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| COIL 3 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| INJECTOR 4 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| INJECTOR 2 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| DIG_IN 4 (PULLED HIGH WEAK 5V) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| DIG_IN 1 (PULLED HIGH WEAK 5V) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| DIG_IN 2 (PULLED HIGH WEAK 5V) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| DIG_IN 3 (PULLED HIGH WEAK 5V) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| LOW SIDE RELAY 18 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| GROUND CHASSIS (GROUNDS (CHASSIS)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| EGT 1 Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| LOW SIDE 2 (2.5A PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 15 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| VBAT IGNITION (VOLTAGE SUPPLY (SWITCHED 12V IGNITION) Linked internally to Pin 15 below.) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LSU HEATER +VE (Wideband Connection (LSU4.9)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LSU HEATER -VE (Wideband Connection (LSU4.9)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA VOLT 3 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA VOLT 4 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LSU UN (Wideband Connection (LSU4.9)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LSU VM (Wideband Connection (LSU4.9)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CAN 1 HIGH Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CAM A VR+ Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CAM A VR- Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| SERIAL 1 GROUND (SERIAL COMMS GROUND) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| SERIAL 1 TX (SERIAL COMMS TRANSMIT RS232 LEVEL) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA VOLT 1 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| INJECTOR 8 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| INJECTOR 5 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| COIL 7 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| COIL 8 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| COIL 2 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| COIL 1 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| INJECTOR 3 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| DIG_IN 6 (PULLED HIGH WEAK 5V) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| USB D+ Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| USB D- Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 11 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| USB VBUS Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE 6 (2.5A PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 17 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| USB GROUND Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 12 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 14 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE 4 (2.5A PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| 5V REF (200mA MAX 5V SENSOR SUPPLY) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| 5V REF (200mA MAX 5V SENSOR SUPPLY) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA TEMP 4 (THERMISTOR INPUT PULLED TO 5V via 2K7) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| ANA VOLT 7 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| LSU IA (Wideband Connection (LSU4.9)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LSU IP (Wideband Connection (LSU4.9)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CAN 1 LOW Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| SENSORS GROUND (SENSOR & COMMS GROUND AND VR SHEILDS) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| KNOCK 1 SIGNAL (KNOCK DSP 1) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| KNOCK 2 SIGNAL (KNOCK DSP 2) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| SERIAL 1 RX (SERIAL COMMS RECIEVE RS232 LEVEL) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA VOLT 2 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA TEMP 2 (THERMISTOR INPUT PULLED TO 5V via 2K7) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| INJECTOR 6 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| COIL 5 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| COIL 6 (IGBT or 5V TTL (Software Selectable)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| GROUND (POWER GROUND TO CHASSIS) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| DIG_IN 5 (PULLED HIGH WEAK 5V) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| INJECTOR 1 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| VBAT (BATTERY VOLTAGE SUPPLY (SWITCHED IGNITION)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| H-BRIDGE A OUT 1 (DBW H-BRIDGE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| H-BRIDGE A OUT 2 (DBW H-BRIDGE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| Stepper 1 / A1 (500mA H-Bridge) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| Stepper 2 / A2 (500mA H-Bridge) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE 5 (2.5A PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| Stepper 3 / B1 (500mA H-Bridge) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| Stepper 4 / B2 (500mA H-Bridge) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 13 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE 1 (2.5A PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE 3 (2.5A PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| LOW SIDE RELAY 16 (100mA Relay Driver) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| 5V REF (250mA MAX 5V SENSOR SUPPLY) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA TEMP 3 (THERMISTOR INPUT PULLED TO 5V via 2K7) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| ANA VOLT 6 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| TACHOMETER (200mA 12V PWM-ABLE) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CRANK VR+ Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CRANK VR- Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| CAM B VR+ Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| CAM B VR- Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME360 and ME442 GEN2 only; not available on ME221 GEN2. | |
| Sensor Ground (Use for Crank Sensor Shields (Typically)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| Not used Cavity: Unused |
Confirmed ME GEN2 wire-in pinout (online manual) |
||
| ANA TEMP 1 (THERMISTOR INPUT PULLED TO 5V via 2K7) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| ANA VOLT 5 (0-5V ANALOG PROTECTED INPUT) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| INJECTOR 7 (2A CONSTANT PROTECTED (6ohm Min Hi Imp)) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
ME442 GEN2 only; not available on ME221 or ME360 GEN2. | |
| GROUND (POWER GROUND TO CHASSIS) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. | |
| GROUND (POWER GROUND TO CHASSIS) Cavity: Populated |
Confirmed ME GEN2 wire-in pinout (online manual) |
Available on ME221, ME360 and ME442 GEN2. |