Why a nonzero time can appear during fuel cut

These are VAG ME7.1 and ME7.5 logging principles; the detailed worked discussion is an S4 M-box example. Confirm the exact ECU, logger definition and injection strategy. During overrun, the ECU may request injection suppression under suitable conditions, but an intermediate bank-level injection-time calculation can remain nonzero.

In a forum-reported M-box case, nonzero ti_b1 during B_sa was first read as evidence that injectors were still firing; the explanation given was that cylinder-specific suppression is applied later in the output path. Bosch's Audi 1.8T ME7.1 function description independently lists bank injection time and the total cut pattern as inputs to ACIFI, with cylinder injection times as outputs. The two sources describe different examples, so verify the actual path in the software being logged.

Signals to distinguish

ExampleInterpretation to verify for the file
B_saAn overrun fuel-cut condition in the cited descriptions. Check its precise meaning and the final output state instead of treating the flag alone as an electrical measurement.
ti_b1 / ti_b2Bank-level calculated injection time supplied to a later output function; it is not necessarily a measurement of an injector pulse.
evz_austot, redistIn the M-box example, a total cylinder-cut pattern and a reduction stage. Check bit order, cylinder assignment and availability in the matched definition; other suppressions can also use a cut pattern.
Per-cylinder output or a suitable electrical measurementEvidence closer to the final command. Confirm that the chosen channel actually reports output and use appropriate test equipment and expertise for a physical measurement.

In that six-cylinder M-box example, the reduction stage was six when all six cylinders were suppressed. That example is not a universal value or a substitute for checking the current cut pattern and ECU definition.

Fuel-cut changes can affect diagnostics. In BBSAWE, the Bosch Audi 132 kW ME7.1 function description warns that generally preventing overrun fuel cut in its gear-0 condition prevents vehicle-speed diagnosis. The function's gear-0 state is not automatically the same as a physical neutral switch on every vehicle. Identify the exact gear and fuel-cut logic before considering a change, especially when diagnosing the reported light-flywheel stall on declutch. See flywheel and stalling diagnosis.

Capture the transition

  1. Record a time window before lift-off, during deceleration and as the pedal returns. Include RPM, vehicle speed, gear, clutch and brake state, coolant temperature, pedal and throttle, and faults.
  2. Log the overrun condition, calculated bank injection time, final cut pattern or reduction state where supported, and lambda request/measurement with sensor readiness. Allow for logging and exhaust-transport delays.
  3. Compare the onset and end of suppression with idle recovery and reapplication. A wideband at its lean display limit during overrun reflects oxygen in the exhaust and does not alone prove a particular injector output or fuel quantity.

Do not infer that a nonzero intermediate time requires a change to minimum injector time. That parameter also affects short-pulse behavior outside overrun and must be evaluated for the actual injector. See overrun and return to throttle, ME7 cold start and throttle transition fueling and injector-change diagnosis.