The module
The PMA1000 is a plug-in air-mass module for a customer’s own measuring housing. A complete meter is a tube that meets the intake, plus an insert that carries the element and the electronics. The PMA1000 is that insert: a thermal flow die, a microcontroller that conditions the signal, and packaging made to the shape of the target housing. Calibration software on a PC matches the module’s output to the curve the control unit already expects.
The die is a PTFD10. It uses the hot-film principle, with the heater carried on a solid thermal-isolation base instead of a thin membrane, so the element stands pressure shock and vibration better. Temperature is read with a thermopile rather than a separate temperature resistor, which raises the signal relative to the noise and simplifies the circuit. A ceramic coating takes abrasive dust. Contaminant on the element can be washed off by immersing the element in solvent. The module detects reverse flow.
Performance
| Item | Value |
|---|---|
| Nominal supply | 14 V |
| Supply range | 8 to 17 V |
| Output | 1 to 5 V |
| Input current | under 30 mA |
| Power | under 250 mW |
| Response | under 8 ms |
| Temperature | −40 to +120 °C |
| Measuring range | 8 to 1000 kg/h |
| Accuracy | within 1.5 % |
| Repeatability | within 0.5 % |
| Pressure drop | under 20 hPa |
| Vibration | up to 150 m/s² |
Heating current can be set within ±20 % of the target curve. Up to 16 calibration points then shape the output in software, so one module can be taught the curve of a particular engine instead of stocking a separate analogue element for every curve. The connector and the position of the element in the housing are part of that same build: the element has to sit at the right height and face the right way in the sample passage.
Connector
| Pin | Function |
|---|---|
| 1 | Not connected |
| 2 | VCC |
| 3 | Ground |
| 4 | Not connected |
| 5 | Output |
Ordering
| Part | Output |
|---|---|
| PMA 1001 | 1 to 5 V, up to 450 kg/h. Curve-compatible with 0280217122 and 0281002757. |
| PMA 1001L | 1 to 5 V, linear, 0 to 353 kg/h. |
An electrical connector is included. One worked example of a non-linear curve, in kg/h and volts, is 0 / 1.003, 6.77 / 1.197, 10.03 / 1.319, 17.45 / 1.554, 33.84 / 1.997, 70.48 / 2.445, 114.4 / 2.845, 165.6 / 3.186, 264.5 / 3.760, 386.2 / 4.297. That list is an example of a fitted curve, not the output of every PMA1000.
A Bosch HFM 5 is calibrated once, as a finished tube and insert. A PMA1000 is calibrated by the builder of the housing, to whatever curve that control unit uses.
Other Posifa packages
Posifa also builds small ported flow modules. They are not the PMA1000 insert, and the five-pin table above does not belong to them. The automotive insert is a bare module for someone else’s intake tube. These have their own hose barbs and their own connectors.