Tuning Wiki
Browse POSiFA

The module

The PMA1000 is a plug-in air-mass module for a customer’s own measuring housing. A complete meter is a tube that meets the intake, plus an insert that carries the element and the electronics. The PMA1000 is that insert: a thermal flow die, a microcontroller that conditions the signal, and packaging made to the shape of the target housing. Calibration software on a PC matches the module’s output to the curve the control unit already expects.

The die is a PTFD10. It uses the hot-film principle, with the heater carried on a solid thermal-isolation base instead of a thin membrane, so the element stands pressure shock and vibration better. Temperature is read with a thermopile rather than a separate temperature resistor, which raises the signal relative to the noise and simplifies the circuit. A ceramic coating takes abrasive dust. Contaminant on the element can be washed off by immersing the element in solvent. The module detects reverse flow.

Performance

ItemValue
Nominal supply14 V
Supply range8 to 17 V
Output1 to 5 V
Input currentunder 30 mA
Powerunder 250 mW
Responseunder 8 ms
Temperature−40 to +120 °C
Measuring range8 to 1000 kg/h
Accuracywithin 1.5 %
Repeatabilitywithin 0.5 %
Pressure dropunder 20 hPa
Vibrationup to 150 m/s²

Heating current can be set within ±20 % of the target curve. Up to 16 calibration points then shape the output in software, so one module can be taught the curve of a particular engine instead of stocking a separate analogue element for every curve. The connector and the position of the element in the housing are part of that same build: the element has to sit at the right height and face the right way in the sample passage.

Connector

PinFunction
1Not connected
2VCC
3Ground
4Not connected
5Output

Ordering

PartOutput
PMA 10011 to 5 V, up to 450 kg/h. Curve-compatible with 0280217122 and 0281002757.
PMA 1001L1 to 5 V, linear, 0 to 353 kg/h.

An electrical connector is included. One worked example of a non-linear curve, in kg/h and volts, is 0 / 1.003, 6.77 / 1.197, 10.03 / 1.319, 17.45 / 1.554, 33.84 / 1.997, 70.48 / 2.445, 114.4 / 2.845, 165.6 / 3.186, 264.5 / 3.760, 386.2 / 4.297. That list is an example of a fitted curve, not the output of every PMA1000.

A Bosch HFM 5 is calibrated once, as a finished tube and insert. A PMA1000 is calibrated by the builder of the housing, to whatever curve that control unit uses.

Other Posifa packages

Posifa also builds small ported flow modules. They are not the PMA1000 insert, and the five-pin table above does not belong to them. The automotive insert is a bare module for someone else’s intake tube. These have their own hose barbs and their own connectors.

Two Posifa PMF2103V flow modules, with P1 and P2 hose barbs and pins on the body.
Marked PMF2103V, and 3 V, with ports P1 and P2. One body brings three pins out of the bottom. The other brings the pins out of the end.
Posifa PMF82000 flow module with two hose barbs and a green edge connector.
Marked PMF82000. Two hose barbs, mounting ears, and a row of contacts on a green edge. The code printed under the part number on this label is a sample marking, not a unit identity.