Tuning Wiki
Browse MoTeC

MoTeC TCMux part 14002, Hall sensor wiring, drawing A01 revision C. The referenced drawing shows M4 and M8 ECU integration; M4 requires software V3.9 or later and M8 V4.1 or later. It limits wiring distance between multiplexer and ECU to 500 mm. Confirm connector orientation against the maker’s drawing. Pin 2 is not identified in that drawing.

PinFunction
18 V supply input
3Left rolling sensor 8 V
4Right rolling sensor 8 V
5Left driven sensor 8 V
6Right driven sensor 8 V
70 V supply input
8Disable switch 0 V
9Left rolling sensor 0 V
10Right rolling sensor 0 V
11Left driven sensor 0 V
12Right driven sensor 0 V
13Coded traction-control signal output to ECU
14Traction-control disable switch
15Left rolling sensor signal S1
16Right rolling sensor signal S2
17Left driven sensor signal S3
18Right driven sensor signal S4

Rolling and driven identify wheel function, not necessarily front and rear. The manufacturer publishes a separate magnetic sensor wiring drawing; do not transfer this Hall sensor arrangement to it. Source: MoTeC TC Mux Hall wiring diagram A01 rev C; MoTeC downloads.