Tuning Wiki

Exhaust-gas recirculation (EGR) returns some exhaust gas to the combustion charge. It is an in-engine emissions control: by diluting the charge and increasing its heat capacity, it reduces peak combustion temperature and the formation of nitrogen oxides (NOx). EGR is used on petrol and diesel engines, but the layout, amount of flow and control strategy depend on the engine and operating conditions.

This guide explains the hardware and control. For specific symptoms and checks see EGR faults; for the relationship to catalysts, particulate filters and emissions testing see Petrol and diesel emissions. EGR and diesel part-load behaviour examines fresh-air mass and load control.

Why recirculate exhaust?

NOx formation is strongly influenced by combustion temperature and oxygen availability. EGR replaces part of the incoming fresh charge with exhaust containing mostly nitrogen, carbon dioxide and water vapour. The diluted charge and its increased heat capacity reduce the temperature rise during combustion, and with it NOx formation. The US Department of Energy's diesel technical primer describes this mechanism and the role of cooled EGR.

EGR flow is a controlled trade-off: excessive recirculation can impair combustion and increase hydrocarbons, carbon monoxide or diesel soot. How much is appropriate changes with load, speed, temperature and the engine's design; there is no universal EGR percentage or temperature threshold to use as a diagnosis. A scan-tool percentage can mean valve position or a calculated rate, so identify the parameter and units before comparing values.

Petrol and diesel engines

Petrol: EGR can lower NOx formation and reduce pumping losses at suitable part-load conditions, improving efficiency on some engines. Many petrol engines also use a three-way catalyst; EGR and the catalyst do different jobs. Depending on the design, dilution may be provided by a separate external circuit, valve timing that retains exhaust internally, or both. The ECU limits dilution to keep combustion stable. Motorservice, EGR overview.

Diesel: the engine normally runs with excess air and its exhaust contains significant oxygen. Cooled EGR can reduce engine-out NOx, but reducing available oxygen also affects soot and combustion. The ECU manages the air and exhaust-gas flows together and may combine EGR with an oxidation catalyst, particulate filter and SCR. Having a DPF or SCR does not itself show whether EGR is fitted or how it is controlled. See the SCR guide and diesel particulate filters.

Internal and external EGR

Internal EGR retains or draws exhaust back into the cylinder through the engine's valve timing; it does not require a separate external EGR valve. Variable valve timing can change the retained amount. A timing or valve-control problem can therefore change internal dilution even when no external valve is fitted.

External EGR takes gas from the exhaust through a passage and controlled valve back to the intake. Depending on the engine, the assembly may include a heat exchanger, bypass flap, pressure or temperature sensors and throttle or exhaust flaps that help create a pressure difference. External EGR can be cooled; internal retained gas cannot pass through an external cooler. The Motorservice layout guide illustrates both approaches.

High-pressure and low-pressure circuits

FeatureHigh-pressure EGRLow-pressure EGR
Typical turbocharged layoutTakes exhaust before the turbine and returns it to the intake downstream of the compressor, often at or near the intake manifold.Takes exhaust downstream of the turbine, in some designs after the particulate filter, and returns it before the compressor.
Flow pathGenerally short and exposed to engine-out exhaust. A valve meters flow; a cooler may be fitted.A longer path can mix recirculated gas through the compressor and charge-air cooler. A cooler and, on some systems, an exhaust flap assist operation.
Workshop concernSoot and oil deposits may restrict the valve, cooler or passages.Identify the actual take-off and return points; cooler deposits, condensation and downstream hardware can affect the circuit. A low-pressure valve is not automatically interchangeable with a high-pressure valve.

These are common examples, not a universal pipe layout. Some engines have high- and low-pressure loops together; others use one, internal EGR, or another arrangement. Use the system schematic for the actual vehicle. Motorservice: high- and low-pressure EGR.

Valve, cooler and actuators

  • EGR valve: meters the external flow. Older designs may use a vacuum diaphragm and a control solenoid; electronic valves use an ECU-controlled actuator and may report valve position. The commanded position is not itself a measurement of the gas actually flowing.
  • EGR cooler: a heat exchanger reduces the temperature of the recirculated exhaust in systems that use one. A cooler bypass can route gas around the core under selected conditions. The exact cooling medium, bypass operation and placement depend on the engine.
  • Cooler and bypass faults: deposits can restrict gas flow or heat transfer; a sticking bypass can leave the wrong temperature. Internal cooler leakage can allow coolant into the exhaust path. Coolant loss and white vapour are not proof of a failed cooler: pressure-test and isolate components as directed by the manufacturer, and investigate other causes.
  • Throttle, exhaust flap and vacuum system: some systems use these to establish the pressure difference needed for EGR flow. Inspect hoses, control valves and connections before assuming that an EGR valve is faulty. HELLA, EGR system checks.

Heat-exchanger fouling can reduce cooling effectiveness even when the cooler is not completely blocked. The Oak Ridge National Laboratory transportation report describes EGR cooler fouling and its effect on heat transfer.

Diesel intake throttle and vacuum control

Some diesel systems use a regulating throttle upstream of the EGR entry to increase the pressure difference that draws exhaust into the intake. It can also close during shutdown to reduce shudder, and may have a role in particulate-filter regeneration. The function and fail-safe position depend on the installation. Check the commanded and actual positions, electrical supply, actuator and any related faults using the correct vehicle procedure; an EGR code does not establish that the throttle is defective. Motorservice: regulating throttle.

On vacuum-operated EGR systems, an electrically controlled valve or pressure transducer regulates the vacuum acting on the EGR diaphragm; a separate change-over valve may vent or isolate it. Check the vacuum source, hoses, control valve and diaphragm as well as the EGR valve itself. Electronically actuated EGR valves may use a different arrangement. Motorservice: pneumatic and electric EGR controls.

How the ECU controls and monitors EGR

The ECU calculates a required flow or position from its calibration and operating inputs. These can include engine speed and load, coolant and intake temperatures, fresh-air mass, manifold or exhaust pressure, valve position and, on some systems, EGR temperature or differential pressure. Sensor fitment and the control model vary; no sensor list or wiring applies to every engine. Bosch describes a differential-pressure sensor used in low-pressure EGR.

On systems using a mass-air-flow sensor, admitting more recirculated gas may reduce the measured fresh-air mass under a suitable controlled condition. The direction and size of the change depend on the system, operating point and other actuators. Compare commanded position, actual feedback and measured airflow with the manufacturer's specified test; an apparently normal position signal does not prove that a blocked passage carries the required flow. HELLA also notes that a faulty air-mass or temperature signal can affect the ECU's EGR calculation. HELLA: diagnosis and indirect influences.

Common EGR problems and symptoms

Fault or observationPossible effectCheck before deciding
Valve or passages restricted or stuck closedInsufficient commanded flow, a fault code or increased engine-out NOx; the driver may notice little.Passages, cooler, actuator supply, hoses, feedback, pressure difference and the air-mass measurement.
Valve stuck or leaking openUnwanted dilution in operating states requiring less EGR; rough running, hesitation or stalling can occur.Commanded state, valve seating, the intake and exhaust for leaks, and other causes of rough running.
Position feedback or wiring faultCommand and reported position disagree, the valve fails an actuator check or a diagnostic fault is stored.Connector, supply, ground, wiring and manufacturer test before replacing the assembly.
Cooler leak or restricted coolerCoolant loss or vapour in the first case; reduced flow or ineffective cooling in the second.Cooling system, cooler isolation and pressure tests, flow path and other possible sources of coolant loss.
Diesel smoke or frequent filter loadingExcess soot may have several causes, including poor air supply, injection or incorrect EGR operation.Airflow, boost, injection, EGR circuit and filter condition together; one symptom does not identify the failed part.

Symptoms depend on the engine and operating state. An EGR-related diagnostic trouble code identifies a monitor or circuit condition, not a confirmed defective valve. The EGR faults page covers valve, cooler, petrol and diesel faults in more depth.

Workshop diagnostic sequence

  1. Identify the system: record the vehicle, engine code, fault and freeze-frame conditions. Obtain the layout, test limits, service bulletins and correct EGR, cooler and actuator descriptions for that engine.
  2. Inspect first: check connectors, wiring, pipes, vacuum hoses, coolant condition and obvious intake or exhaust leaks. Consider other stored faults and the health of airflow and temperature sensors.
  3. Establish operating conditions: confirm engine temperature, load and diagnostic test prerequisites. Compare requested and actual valve positions, fresh-air mass and other relevant values using the maker's instructions.
  4. Separate actuation from flow: if supported, run the approved actuator test and verify the expected airflow, pressure or temperature response. Position feedback alone cannot show that passages are clear. On a vacuum-controlled valve use a hand vacuum pump only in the specified manner; do not apply arbitrary electrical power or vacuum to an unknown actuator.
  5. Confirm the cause: inspect deposits, valve movement, pressure and cooler/bypass function as appropriate. Follow the manufacturer's procedure for removal, coolant pressure checks, cleaning or replacement and any adaptation. Do not reset learned values as a substitute for repairing the underlying fault.
  6. Verify repair: restore connections and coolant correctly, check for leaks, clear faults when appropriate, and repeat the prescribed checks and drive cycle. Record conditions and results.

Allow hot exhaust and coolant components to cool and follow the manufacturer's safe working and coolant-handling instructions. Use appropriate exhaust extraction for running checks: HSE vehicle exhaust guidance.

MOT and emissions testing

The DVSA MOT manual, section 8 says visible and identifiable diesel emissions-control components, including EGR valves, are inspected; missing, obviously modified or obviously defective manufacturer-fitted equipment is a listed defect. The applicable smoke or petrol gas check does not by itself measure an engine's NOx across a driving cycle. See emissions testing equipment for the measurements and their limits. Consult the current manual and the vehicle-specific procedure.

Sources and related pages