Tuning Wiki
Applies to

Check the hardware and software limits stated in this article.

The AEM EMS Series 2 30-6101 is an application-specific plug-in ECU. The AEM instructions identify the 1993–1998 Toyota Supra non-turbo and 1993–1997 Lexus SC300/GS300; the connector diagram is specifically titled 1993–1997 Supra/Lexus 2JZ-GE. Check the exact engine, year and harness before installation.

AEM Series 2 30-6052 ECU
AEM 30-6052 shown as a Series 2 family illustration; connectors and applications differ. AEM / Holley product photograph, reproduced with permission.

Connector assignments

Transcribed from the 30-6101 connection diagram, PDF pages 9–11. Follow the connector diagram and orientation in the manual. A dash is the source’s entry and does not by itself establish an unused or safe connection; available channels depend on configuration. At 4A, the source describes the vehicle brake input as 12 V but the EMS note says the switch must connect to ground: resolve the difference with AEM and the actual harness before wiring.

Connector A

PinVehicle functionAEM EMS functionI/OAvailability and notes
1AIgnition Switch (+12V when key on)Main Relay circuitInputDedicated, activates Switch 1 input
2AVehicle Speed Signal – from Odo/Trip meterT3 (Vehicle Speed)InputPnP for Vehicle Speed signal
3AKickdown switchSwitch 3InputAvailable, switch must connect to GND
4ABrake switch input (12V)Switch 6InputAvailable, switch must connect to GND
5A---------Not Used
6AW- Malfunction Indicator LampLS10OutputAvailable, switched GND output (1.5A max)
7A---ATPR (GEAR)InputReserved for future use
8ASDL to datalink connector (96-97 only)------Not Used
9A2nd gear indicator input (A/T only)ATP2 (GEAR)InputReserved for future use
10A1st gear indicator input (A/T only)ATP1 (GEAR)InputReserved for future use
11A---CAN1LOutputDedicated
12AOD1 to cruise control ECU (AT only)CAN1HOutputDedicated
13A---Reserved---Reserved for future use
14A---Reserved---Reserved for future use
15AELS for Idle up Diode------Not Used
16ATacho signal (from ignitor)------Not Used
17ATT sig to DATALINK connector (A/T only)Injector 12OutputAvailable, P&H Injector driver 4A/1A
18AA/T pattern select sw (A/T only)Switch 5InputAvailable, switch must connect to GND
19ATE2 sig to DATALINK connectorInjector 11OutputAvailable, P&H Injector driver 4A/1A
20ATE1 sig to DATALINK connector------Not Used
21ADI from Fuel Pump ECU------Not Used
22AFuel pump control (FPC) signalCoil 8 / LS8OutputPnP 0- 5V FPC signal, not for use with relays
23AACMG to A/C Magnetic clutchLS6OutputPNP for A/C compressor relay
24AMain Relay ControlMain Relay (HS2)OutputDedicated, activates Main Relay with 12V
25AManual indicator light (A/T only)ATIND (Coil7)OutputPNP manual mode indicator (auto only)
26A---EFI-TRCInputDedicated
27A---EFI+TRCInputDedicated
28AOver Drive Switch input (A/T only)Switch 4InputPNP for Overdrive input (auto only)
29A---Baro (ADCR12)InputAvailable, Spare 0-5V Sensor Input
30ASub O2 signal (CA only)------Not Used
31A+12V Power from main relay+12V SwitchedBothDedicated
32A+12V Power from main relay------Not Used
33A+12V permanent battery backup powerPermanent +12VInputDedicated, used to store internal datalog
34AA/C signal from A/C amplifierADCR11 (Switch 7)InputPNP for Air Conditioning request switch
35A---HALLPWROutput+12V Output
36ASub O2 sensor heater control (CA only)Injector 8OutputSpare P&H Injector 4A/1A
37A---------Not Used
38A---LS7---Available, switched GND output (1.5A max)
39A---------Not Used
40A---------Not Used

Connector B

PinVehicle functionAEM EMS functionI/OAvailability and notes
1B---Timing GroundOutputDedicated
2B---EGT 1InputJumper set for 0-5V input (100kΩ pull-up)
3BVSS GroundTiming GroundOutputDedicated
4BE11EGT 2InputJumper set for 0-5V input (100kΩ pull-up)
5BCam Sensor 2 (NE2) Ground------Not Used
6B---Timing GroundOutputDedicated
7BDistributor GroundTiming GroundOutputDedicated
8BAuto Trans Sol No3 S3 (Auto Trans only)EGT 3InputJumper set for 0-5V input (100kΩ pull-up)
9BAuto Trans Sol No2 S2 (Auto Trans only)HS3OutputAvailable, switched +12V output (1.5A max)
10BAuto Trans Sol No1 S1 (Auto Trans only)HS4OutputAvailable, switched +12V output (1.5A max)
11B---+5V Sensor powerOutputDedicated, sensor only
12B---Reserved---Reserved for future use
13B---Reserved---Reserved for future use
14B---Reserved---Reserved for future use
15BInjector 6Injector 6OutputPnP Injector 6 (P&H 4A/1A driver)
16BInjector 5Injector 5OutputPnP Injector 5 (P&H 4A/1A driver)
17BInjector 4Injector 4OutputPnP Injector 4 (P&H 4A/1A driver)
18BInjector 3Injector 3OutputPnP Injector 3 (P&H 4A/1A driver)
19BInjector 2Injector 2OutputPnP Injector 2 (P&H 4A/1A driver)
20BInjector 1Injector 1OutputPnP Injector 1 (P&H 4A/1A driver)
21B---Switch 2InputAvailable Switch input
22B---------Not Used
23BNo.2 Speed sensor (Auto Trans only)T4 (Spare Speed)InputAvailable magnetic speed sensor input
24BAuto Trans Fluid Temp (Auto Trans only)ADCR14InputAvailable 0-5V input, 2.2kΩ pull up to 5V
25BDistributor Cam signal 2 (G2) input------Not Used
26BDistributor Cam signal 1 (G1) inputCam (T2) signal +InputDedicated
27BDistributor - Crank signal (NE) inputCrank signal +InputDedicated
28BVF2 sig – to Datalink connector 1 – pin14Sensor GroundOutputDedicated, Sensors only
29BVF1 sig – to DATALINK connectorIDLE7OutputAvailable, switched Ground / +12V, 1.5A max
30B---IDLE8OutputAvailable, switched +12V/Ground, 1.5A max
31B---+12V SwitchedOutputDedicated
32BISC4 (pin 3 on ISC harness)IDLE4OutputPNP Idle control motor,
33BISC3 (pin 6 on ISC harness)IDLE1OutputPNP Idle control motor
34BISC2 (pin 1 on ISC harness)IDLE3OutputPNP Idle control motor
35BISC1 (pin 4 on ISC harness)IDLE2OutputPNP Idle control motor
36BFuel Pressure Up solenoid valve (93-96)IDLE5OutputAvailable, switched Ground / +12V, 1.5A max
37B---IDLE6OutputAvailable, switched +12V/Ground, 1.5A max
38B---LS4OutputAvailable, switched GND output (1.5A max)
39BACIS solenoid – (intake runner length valve)LS5OutputPNP for ACIS valve
40B---LS3OutputAvailable, switched GND output (1.5A max)
41B5V Reference+5V SensorOutputDedicated
42B---------Not Used
43BTPS signal input (VTA1)TPSInputDedicated, 2.2kΩ pull-up resistor to 5V
44BCoolant Sensor InputCoolantInputDedicated, 2.2kΩ pull-up resistor to 5V
45BAir Temp SensorAir TempInputDedicated
46BEGR gas Temp Sensor------Not Used
47BOX2 (rear O2 sensor)O2 #1InputDedicated, 0-5V signal
48BOX1 (front O2 sensor)O2 #2InputDedicated, 0-5V signal
49BRear Knock SensorKnock 2InputDedicated, software knock filter
50BFront Knock SensorKnock 1InputDedicated, software knock filter
51B---------Not Used
52B---Coil 6OutputAvail. Coil6 output, 0-5V falling edge trigger
53B---Coil 5OutputAvail. Coil5 output, 0-5V falling edge trigger
54B---Coil 4OutputAvail. Coil4 output, 0-5V falling edge trigger
55B---Coil 3OutputAvail. Coil3 output, 0-5V falling edge trigger
56B---Coil 2OutputAvail. Coil2 output, 0-5V falling edge trigger
57BIgniter Control (IGT)Coil 1OutputPnP Coil1 output, 0-5V falling edge trigger
58BIgniter return (IGF) to ECU------Not Used
59B---LS11OutputAvailable Switched Ground 1.5amp max
60B---PW2OutputAvailable boost control solenoid output
61B---------Not Used
62B---MAPInputDedicated
63B---------Not Used
64BIdle1 Sw from TPS------Not Used
65BSensor GroundSensor GroundOutputDedicated, Sensors only
66BVG signal for Airflow meterMAFInputAvailable 0 to 5v input, 100k pull-up to 5V
67B---EGT 4InputJumper: 0-5V, thermistor or EGT pull up
68B---LS9OutputAvailable Switched Ground 1.5amp max
69BE1- GroundPower GroundBothDedicated
70B---Injector 7OutputAvailable P&H Injector driver 4A/1A
71BOx 1 Heater Ground (96-97)LS12OutputAvailable Switched Ground 1.5amp max
72BHT2 – rear O2 heater control (CA only)LS2OutputAvailable Switched Ground 1.5amp max
73BHT1 – front O2 heater control (CA only) / Fuel Pressure up solenoid (1997)LS1OutputAvailable Switched Ground 1.5amp max
74BEVAP SolenoidInjector 9OutputAvailable P&H Injector driver 4A/1A
75BEGR SolenoidInjector 10OutputAvailable P&H Injector driver 4A/1A
76BPark / Neutral position switch (AT only)ATPNP (Gear)InputReserved for future use
77BCranking signal input (12V)------Not Used
78BChassis Ground - EO3 (96-97)Power GroundBothDedicated
79BChassis Ground – EO2Power GroundBothDedicated
80BChassis Ground – EO1Power GroundBothDedicated

Documentation

AEM 30-6101 installation instructions and connection diagram. The manual’s separate Series 1 versus Series 2 comparison identifies changed assignments; do not substitute the 30-1101 pinout.