Map Definition Extractor

Extract maps from supported definition formats to a WinOLS CSV. Review the limitations and omissions before importing into the matching firmware project.

Extract maps from a definition file

Choose one supported A2L, A2LZ, A2LC, ECA, KP, OLS, XDF or BTT2 definition, or an experimental legacy DRT or EDC15 DAMOS file. Older KP formats are experimental. Files are limited to 64 MiB; compatibility is checked from the contents.

Up to 64 MiB, from the same firmware version and read layout. Some definitions need it to read stored axis counts. CPU addresses may also need a mapping to your file offsets.

This service is free. Upload first, then sign in or create a free account to process your files and save your results.

Supported map definition formats

The file extension alone cannot establish compatibility. Each extraction reports what was read, what was exported and what was omitted.

Current supported definition profiles
InputSupported profile
A2LSelf-contained definitions within the supported scalar, curve and table subset. Unsupported layouts or scaling may omit individual maps.
A2LZ / A2LC / ECASupported containers are decoded to A2L and use the same definition subset. Decoded A2L is limited to 64 MiB. The report records decoder and integrity details.
KP / OLSUnencrypted KP format 839 and OLS formats 503, 597, 750, 804 and 839. Experimental older KP formats 116, 245, 292, 503 and 597 require a matching-size binary and the service helper; results must be checked carefully. Older OLS projects need a verifiable embedded binary and a complete map stream. Format numbers are internal file versions, not WinOLS product versions. Encrypted OLSX is unsupported.
DRT (experimental)Complete legacy STD0_100 drivers only. Values are assumed unsigned 8-bit, factor 1, offset 0 and percent units; nonzero axis addresses assume 16-bit little-endian values. Zero axes use indices. These assumptions are not verified. Catalogue reference data may provide descriptions or a partial driver hash comparison; this does not verify the full firmware or DRT contents. Other layouts are rejected.
BTT2Named-column WinGuiBot BTT2 maps within the supported storage and scaling subset. Source data and matching firmware are not independently verified.
DAMOS (experimental)Line-oriented EDC15 .dam files with a raw binary. Addresses, 16-bit big-endian geometry and signedness are assumed; scaling and units are left blank. The binary is checked for bounds, not identity. Other families and layouts are unsupported.
XDFUnencrypted XDF XML 1.60, 1.70 or 1.80, within the supported layout and scaling subset.

Only saved definitions are exported. Potential maps are not regenerated, and definitions are not transferred to another firmware version. A partial export contains only the supported maps; always review the omission count and report.